background image

12

5.6. Maintenance, Calibration, Test Procedure & Service

This section contains information and instructions concerning maintenance of the DS-520

Weighing Scale.

Preventive maintenance consists of periodically cleaning the external surfaces of the instrument

and should be performed as often as operating conditions warrant.

The calibration procedure is designed to be an aid in maintaining the scale accuracy within

specifications.  The calibration procedure may also serve as a performance test procedure.

CAUTION: DO NOT ATTEMPT ANY SERVICE WHILE THE INSTRUMENT IS

CONNECTED TO THE POWER SOURCE.

5.6.1. Maintenance Procedures

5.6.1.1. EXTERIOR MAINTENANCE

The exterior surfaces of the counting scale can be easily cleaned using soap and water.

For grease or other difficult spots, a chlorothane or naptha based cleaner may be used.

5.6.1.2. Internal Maintenance

Internal maintenance is not normally required and if it is, should not be attempted except

by a qualified, authorized service technician.

5.6.2. Calibration

The following procedure should be followed periodically (every six to twelve months is

suggested) to determine that the scale is functioning in all modes.

A.

Electrical

Follow section 4.0 through all its steps

B.

Accuracy

Weighing:  The scale weighing accuracy can be determined by applying various known

weights to the platform.  Because of the scale's very high accuracy, only weights that are

certifiably more accurate than the scale's specifications should be used in testing for

accuracy. (NIST class "F" or higher)

Since the scale owner does not normally have such certifiable weights available, it is suggested

that the customer call their authorized DIGI dealer.

5.6.3. Service & Repair

No service or repair should be attempted except by qualified personnel, and not until it has

been positively determined that the weighing scale requires such service.  All service

should be done in a clean, dry, dust-proof area.

Содержание DIGI DS-520

Страница 1: ...O O O Op p p pe e e er r r ra a a at t t tii i io o o on n n nM M M Ma a a an n n nu u u ua a a all l l D D D Dii i ig g g gii i it t t ta a a all l l II I In n n nd d d dii i ic c c ca a a at t t to...

Страница 2: ...0 INSTALLATION 5 6 3 1 Un packing 5 3 2 Inspection 5 3 3 Re packing 5 3 4 Un locking Procedure 5 6 4 0 DS 520 OPERATIONAL PROCEDURES 7 8 4 1 Power On Off 7 4 2 Automatic Shut Off 7 4 3 Re zero 8 4 4 T...

Страница 3: ...ntinuous use Fast self test procedure when power on Selectable automatic shut off time which prolongs battery life Two point low battery detect A When battery is weak the battery indicator will light...

Страница 4: ...ght display to zero TARE Key Set or clear a tare ON OFF Key Turn the power ON or OFF 1 4 Indicators Lamps Zero On when zero point is adjusted and when weight is stable Net On when tare reduction is pe...

Страница 5: ...humidity 15 85 RH Power consumption 0 07w when 6V 0 1w when 9V 2 1 3 Analog specification Input sensitivity 0 67mV V 10kg 20kg all other capacities 1mV V Zero adjust range 40 Full Scale Zero balance...

Страница 6: ...ection of the scale should be performed If any damage has been incurred during transportation notify the shipper and Rice Lake Weighing systems immediately Instructions for assessment of damage and fu...

Страница 7: ...6 Unlocking Procedure Continued...

Страница 8: ...lay will then briefly show all segments then blank for a second then go into weighing mode 1 Begin with the scale turned off 2 Press and hold the ON OFF key for 6 seconds This sets the Timer for 10 mi...

Страница 9: ...howing 0 00 Example based on 60 lb scale 1 Place 25 lb on the scale 2 Press the REZERO key The display will show all segments briefly then go to 25 00 25lb exceeds the 40 limit of the rezero range 4 4...

Страница 10: ...0 0 1 1 5 Press the TARE key To store spec data and advance to the next spec S1 0 0 0 6 Press the REZERO key To save specs to memory and return to the weighing mode 5 2 Specification Entry and Span Ad...

Страница 11: ...en span is calibrated the scale will return to the weighing mode 60 00 NOTE To exit maintenance mode Press the REZERO key at any step except when are displayed 5 3 Internal Count Display Example Begin...

Страница 12: ...Used S5 Not Used S6 Auto Tare Clear V 1 21 0 yes 1 no 5 5 Error Message List The following message will appear when an invalid operation is performed Message Remark Appropriate Operation OF When displ...

Страница 13: ...nternal maintenance is not normally required and if it is should not be attempted except by a qualified authorized service technician 5 6 2 Calibration The following procedure should be followed perio...

Страница 14: ...ccident misuse neglect alteration improper installation improper repair or improper testing RLWS shall be the sole judge of all alleged non conformities Such equipment has not been modified altered or...

Отзывы: