9
5.0. MAINTENNCE MODE
5.1. Specification Entry
Example : Begin in the weighing mode with the scale showing 0.00
1. Press and hold [REZERO] key, while holding the [REZERO] key, press [TARE] [TARE]
[ON/OFF] then release the [REZERO] key. The display will show all 8’s while holding the
[REZERO] key, when the [REZERO] key is released the scale will be in the Maintenance Mode.
2. Press the [TARE] key. The display will show the software version.
3. Press the [TARE] key. The display will show S0 0 0 0 (spec 0 = 0 0 0)
4. Press the [ON/OFF] key. To change spec data (0 0 0 – 1 1 1)
Ex: Press [ON/OFF] S0 0 0 1, Press [ON/OFF] S0 0 1 0, Press [ON/OFF] S0 0 1 1,
5. Press the [TARE] key. To store spec data and advance to the next spec. S1 0 0 0
6. Press the [REZERO] key. To save specs to memory and return to the weighing mode.
5.2. Specification Entry and Span Adjustment
Example : Begin in the weighing mode with the scale showing 0.00
1. Press and hold [REZERO] key, while holding the [REZERO] key, press [TARE] [TARE]
[ON/OFF] then release the [REZERO] key. The display will show all 8’s while holding the
[REZERO] key, when the [REZERO] key is released the scale will be in the Maintenance Mode. The
display will show d5-671.
2. Press the [TARE] key. The display will show the software version.
3. Press the [TARE] key. The display will show S0 0 0 0 (spec 0 = 0 0 0)
4. Press the [ON/OFF] key. To change spec data (0 0 0 – 1 1 1)
Ex: Press [ON/OFF] S0 0 0 1, Press [ON/OFF] S0 0 1 0, Press [ON/OFF] S0 0 1 1,
Содержание DIGI DS-520
Страница 7: ...6 Unlocking Procedure Continued...