8.3 Software Update
For use with ScaleCore3 Printed Circuit Assembly (Circuit Board)
Equipment Requirements
• PC with terminal program
• Interface Cable PN: 503230-0001 (10') or -0002 (5')
Updating Process
1. Connect interface cable to P2.
Figure 8-1. Connecting Interface Cable
2. Power on the scale.
3. Open the terminal program.
Figure 8-2. Serial Port Setup
4. Configure to the following:
• Baud Rate: 38400
• Data Bits: 8
• Parity: None
• Stop Bits: 1
• Flow Control: XON/XOFF