Appendix
© Rice Lake Weighing Systems
●
All Rights Reserved
61
11. When firmware has been updated, a success prompt displays.
12. Select
OK
to close the window.
Figure 7-18. Firmware Success Prompt
13. After firmware update is completed, allow device to reboot if it power cycles.
14. Power off Ai-1 indicator and remove serial cable.
15. Attach a serial cable to the wheel weigh pad’s serial port and connect free end to computer.
NOTE: The wheel weigh pad’s serial port is located inside the electronics cover on the CPU board.
Figure 7-19. Wheel Weigh Pad Serial Port
16. Run wheel weigh pad firmware executable.
17. Repeat steps
Step 6
through
Step 14
.
18. Reinstall wheel weigh pad’s electronics cover and protection plate with previously removed hardware (
Figure 7-5 on
page 55
).
19. Repeat steps
Step 14
through
Step 18
.for remaining wheel weigh pads.
EXC-
SIG+
SIG-
EXC+
SIG-
SEN+
SEN-
SIG+
EXC-
EXC+
EXC-
SIG+
SIG-
EXC+
EXC-
SIG+
SIG-
EXC+
CELL2
CELL4
CELL3
CELL1
J2
SENSE
+5V GND
COM 1
COM 1
B[-]
A[+]
GND
RX
CTS
TX
RS232/RS485
RS232
01 02
J4
ON
+5V
GND
J 1
CAL
RS232
COM 2
SENSOR
BOOT
J3
CTS
RX
TX
+5V GND TX RX
COM2 TTL
COM 1
B[-]
A[+]
GND
RX
CTS
TX
RS232/RS485
Содержание 181881
Страница 72: ...Load Ranger Wheel Weigh Pad System 66 Visit our website www RiceLake com...
Страница 73: ......