background image

12

Installation

Grounding Instructions

This appliance must be grounded. If it should malfunction or breakdown, 

grounding provides a path of least resistance for electric current to 

reduce the risk of electric shock. This appliance is equipped with a cord 

having an equipment-grounding conductor and grounding plug. The plug 

must be inserted into an appropriate outlet that is properly installed and 

grounded in accordance with all local codes and ordinances. No adaptor 

should be used with this appliance.

WARNING

Improper connection of the equipment-grounding conductor can result in 

a risk of electric shock. Check with a qualified electrician or service person 

if you are in doubt as to whether the outlet is properly grounded. Do not 

modify the plug provided with the appliance – if it will not fit the outlet; have 

a proper outlet installed by a qualified electrician.

120 V  Models

This appliance is for use on a nominal 120 V circuit, 

and has a grounded plug 

(figure 9)

. Make sure that 

the appliance is connected to an outlet having the 

same configuration as the plug. No adaptor should 

be used with this appliance.

220 V/240 V  Models

 

(H110 only)

This appliance is for use on a circuit having a nominal 

rating more than 120 V and is factory-equipped with 

a specific cord and plug to permit connection to a 

proper electric circuit. Make sure that the appliance is 

 connected to an outlet having the same configuration as 

the plug. No adaptor should be used with this  appliance. 

If the appliance must be reconnected for use on a 

 different type of electric circuit, the reconnections should 

be made by a qualified service personnel.

figure 9

Содержание Hybrid Central Vac

Страница 1: ...intenance Troubleshooting Warranty Information OWNER S MANUAL DOMESTIC USE ONLY Please read this document carefully before installing and or using your vacuum cleaning system Model ________________ Se...

Страница 2: ...pliance is not working as it should has been dropped damaged left outdoors or dropped into water return it to a service center 6 Do not pull or carry by cord use cord as a handle close a door on cord...

Страница 3: ...Low Voltage Connections 13 Operating instructions Hose Hook up Inlets 14 Progressive Start 15 Automatic Stop 15 LED indicator 15 Information center 15 Maintenance Motor 16 Use with bag 17 Use without...

Страница 4: ...Our exten sive network of qualified professionals ensures first quality service near you Contact us for the location of the Riccar authorized service center in your area Schematic 1 Circuit Breaker 2...

Страница 5: ...ox and small saw or a pipe cutter figure 2 See pages 8 and 9 for general instructions pertaining to the preparation of PVC pipes To simplify matters installation kits including necessary fittings pipe...

Страница 6: ...right air intake figure 6 and put it on the left air intake Making sure that the tabs are aligned with the notches push the cap completely in figure 7 6 From the inside of the vacuum insert the bag ad...

Страница 7: ...allation Utility Valve installation H40 H60 H110 models 1 Secure the T elbow on the air intake see page 5 figure 3 2 Install the utility valve on the T elbow 3 Connect the low voltage wiring see pages...

Страница 8: ...8 Installation Dos Don ts Installing Conduits...

Страница 9: ...9 Installation Dos Don ts Installing Conduits...

Страница 10: ...acuum inlets we recommend that the principle of electric polarity be taken into account Ensure that the wire connected onto contact A on inlet 1 is the same as that connected to contact A on inlet 2 a...

Страница 11: ...Do not use extension cords or modify the length of your vacuum cleaner s power cord Dedicated grounded circuit North America 120 V 240 V All models 15A Your central vacuum cleaner has a thermal safet...

Страница 12: ...operly grounded Do not modify the plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician 120V Models This appliance is for use on a no...

Страница 13: ...ently press on the toggle to open the connector figure 11 3 Insert stripped wire figure 12 4 Release toggle to secure wire in connector figure 13 5 Repeat for second wire To disconnect 1 Gently press...

Страница 14: ...heck rubber seals in each vacuum inlet Plug the hose alternatively into each vacuum inlet to ensure that each one works properly While the hose is still plugged into one inlet and the system is opera...

Страница 15: ...um system with the switch on the hose handle LED Indicator H10 H20 H40 models LED On low voltage connector Steady green indicates unit is connected to a power source Information center H60 H110 models...

Страница 16: ...purposes this should be done by an authorized service center Brush life is affected by the number of hours used frequency of start ups and shut downs humidity altitude and tem perature In order to avo...

Страница 17: ...seal bag opening adhesive seal provided on each bag Discard used bag 3 Install the new bag ensuring the tabs on the bag adaptor are aligned with the slots in the bag collar figure 16 4 Ensure adequat...

Страница 18: ...figure 19 Do not remove the filter Wrap the filter and the lower portion of the unit body within a large plastic bag Hold it tightly around the unit with one hand With your other hand gently shake the...

Страница 19: ...o clips and remove the dust receptacle see page 17 figure 15 3 Remove the bag see page 17 4 Pull the bag adaptor out of the air intake see page 6 figure 5 5 Put the other adaptor provided in the air i...

Страница 20: ...ons are provided by an electronic timing board only as a reference guide To do so 1 Unlatch the opening on the carbon filter case and gently flip it upward figure 21 2 Remove the used filter and disca...

Страница 21: ...ric outlet then empty and wipe the dust recipient with a dry cloth Then operate the system from the vacuum inlet through which you vacuumed the liquid in order to eliminate all moisture in the piping...

Страница 22: ...ecipient to make sure they are tight and dirt recipient is aligned Open vacuum inlet Close all vacuum inlets not in use Exhaust line is clogged Verify that no object is blocking the exhaust Blocked ho...

Страница 23: ...re 3 on page 5 Start the unit by plugging the hose into a vacuum inlet By placing your extended hand over the air intake opening on the unit check the suction strength on the unit itself If suction st...

Страница 24: ...inlets in your home to identify the defective inlet Faulty switch Push the switch on the power unit to the on position If the system starts the problem lies within the low voltage wiring Unit circuit...

Страница 25: ...ensure adequate contacts for the hose switch to function see page 14 Defective on off hose If the hose is properly placed in the vacuum inlet and the unit continues running despite the fact that the h...

Страница 26: ...tral system an authorized Riccar retailer should be contacted The retailer will repair or replace at our option any defective part or parts at your location at no labor cost for a period of three 3 ye...

Страница 27: ...ll 1 888 9SIMPLY or visit the Riccar website at www riccar com THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY AND ALL OTHER WARRANTIES WHETHER WRITTEN ORAL EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY O...

Страница 28: ...www riccar com 1 888 6 RICCAR IMPMOD967 JA 15...

Отзывы: