17
Maintenance
Maintenance
Use with bag
Change the bag when the one in place is full. Frequency will depend on
the use of the unit. For the H60 & H110 models, the information center
will indicate when to change the bag. These indications are provided by
an electronic timing board, only as a reference guide.
1. To access the bag, unlatch the two clips and
remove the dust receptacle
(figure 15)
.
2. Remove the used bag and seal bag opening
(adhesive seal provided on each bag). Discard
used bag.
3. Install the new bag, ensuring the tabs on the
bag adaptor are aligned with the slots in the
bag collar
(figure 16)
.
4. Ensure adequate sealing by inserting bag as
far as the retention ring
(figure 17-A)
.
Rotate bag 20°
(figure 17-B)
to ensure tabs
on bag adaptor are no longer aligned with the
slots in the bag collar.
5. Replace dust receptacle and seal by latching
both clips.
Use only genuine Riccar replacement bags.
Failure to do so could
void the warranty on your vacuum unit.
retention ring
tabs on bag adaptator
A
B
figure 15
figure 16
figure 17