3.2- General safety instructions 
READ ALL THE INFORMATION BEFORE OPERATING THE PRODUCT. 

1. Keep work area clean

 

Cluttered areas and benches invite accidents and injuries.

 

2. Consider work area environment

 

Keep work area well lit (natural light or sufficient artificial lighting). 
Keep work area well ventilated. 
Do not use product where there is risk to cause fire or explosion (in the presence of flammable liquids, 
solids or gas).

 

3. Guard against electric shock

 

Avoid body contact with earthed or grounded surfaces (e.g. pipes, radiators, ranges, refrigerators).

 

4. Keep children away

 

Do not let bystanders touch the product or its power cable or extension cord.  
All bystanders (esp. children) should be kept away from product and work area. 
Keep the product away from children or from their environment. Never allow children to operate the 
appliance. Children should be supervised to ensure that they do not play with the appliance. 
5. Store idle products 
When not in use, product should be stored in a dry, high or locked up place, out of reach of children. 
6. Do not force the product 
It will do the job better and safer at the rate speed for which it is intended. 
Do not use the product for purposes other than those for which it is intended. The product will do a 
better and safer job if it is used only for the purposes it was designed for. 
7. Use the right product 
Do not force small products or attachments to do the job of a heavy duty product.  
8. Dress properly 
When installing, do not wear loose clothing or jewellery; they can be caught in moving parts.  
Wear protecting hair covering to contain long hair. 
9. Use protective equipment 
When installing, wear protective equipment appropriate to working conditions and work 
environment 
Wear protective helmet, safety goggles, ear mufflers, face or dust mask, rubber gloves and non-skid 
footwear to reduce the risk of personal injury during products use or manipulation. 
10. Do not abuse the power cable 
Never carry the product by the cable or yank it to disconnect it from the socket.  
Keep the cable away from heat, oil and sharp edges. 
Inspect product cable periodically and if damaged have it repaired by an authorized service facility.  
Inspect extension cords periodically and replace, if damaged.  
11. Do not overreach 
Keep proper footing and balance at all times. 
12. Maintain product with care 
Keep product clean for better and safer performance.  
13. Disconnect product 
When not in use, before servicing and when changing accessories. 
14. Avoid unintentional starting 
Ensure switch is off when plugging in. 
15. Use of extension leads  
When product is used with extension cord, ensure that extension cord withstands product ratings. 
If used outdoors, use only extension cords intended for outdoor use. 
16. Stay alert 
Watch what you are doing. Use common sense.  
Do not operate product when you are tired, under the influence of alcohol, prescription medicines or 
drugs. 
17. Check damaged parts 

Содержание RIBILAND PRPVC751CIP

Страница 1: ...BLE PUMP User and maintenance manual IT POMPA SOMMERSA Manuale di istruzioni e di manutenzione R f Art Nr PRPVC751CIP 511246 PRPVC901CIP 511276 Imp par by Ribimex S A 56 Route de Paris FR 77340 Pontau...

Страница 2: ...e injury and or damages Please keep this manual for future reference AVVERTENZA Leggere attentamente questo manuale di istruzioni prima di utilizzare l attrezzo Il funzionamento non corretto pu causar...

Страница 3: ...1 Symboles signification des symboles pr sents sur le produit le cas ch ant Signale un risque de blessures graves et ou dommages et ou de d t rioration du produit en cas de non respect des consignes...

Страница 4: ...lisez pas ce produit pour des travaux auxquels il n a pas t destin Il ex cutera mieux son travail et d une mani re plus s re s il est uniquement utilis pour l usage auquel il a t destin 7 Utiliser le...

Страница 5: ...ilisateur 21 Remarques Les consignes de s curit et les instructions indiqu es dans la pr sente notice ne sont pas en mesure d illustrer d une mani re exhaustive toutes les conditions et les situations...

Страница 6: ...La section des conducteurs du c ble doit tre gale ou sup rieure 1 mm2 Le c ble ne doit pas tre plus l ger que les c bles de type H05 RN F 6 Pour d brancher le c ble d alimentation du socle de prise d...

Страница 7: ...n raccourcissant la longueur du c ble entre la pompe et le flotteur il est possible de modifier les hauteurs d eau correspondantes au d marrage et l arr t de la pompe 3 Pour cela utiliser l attache ra...

Страница 8: ...ide sans eau La pompe n est pas pr vue pour une utilisation en continue Ne pas faire fonctionner la pompe plus de 24heures en continue La pompe submersible doit obligatoirement tre immerg e avant la m...

Страница 9: ...Positionner le flotteur plus haut Pas de d bit Orifices d aspiration bouch s Tuyau pli Nettoyer les orifices d aspiration repositionner le tuyau correctement La pompe ne s arr te pas Le flotteur ne c...

Страница 10: ...3 1 Symbols explanation of the symbols found on the product when applicable Caution Risk of injury and or damage and or deterioration of product in case of non compliance to safety requirements Read...

Страница 11: ...ct Do not force small products or attachments to do the job of a heavy duty product 8 Dress properly When installing do not wear loose clothing or jewellery they can be caught in moving parts Wear pro...

Страница 12: ...nce can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or inst...

Страница 13: ...the hose connection 6 section corresponding to the internal diameter of the hose 3 Add a fixing collar hose clamp not supplied to complete the seal 4 3 Adjusting the floating switch 1 The float switc...

Страница 14: ...continuous operation e g continuous water circulating operation Avoid running pump for more than 24hours The submersible pump must be immersed before switching on Place pump into water then let it pu...

Страница 15: ...ch Check mains power supply Bring floater in a higher position No flow Inlet is clogged Pressure hose in bent Clean inlet water jet Reset hose Pump does not switch off Floater can not sink down Place...

Страница 16: ...endi ferite e danni 3 1 Simboli Spiegazione dei simboli usati sull elettroutensile ove applicabile Attenzione Rischio di lesioni e o danni e o deterioramento dell attrezzo in caso di non conformit ai...

Страница 17: ...impigliarsi nelle parti in movimento Se si hanno i capelli lunghi indossare un casco 9 Usare indumenti di sicurezza Durante l installazione indossare indumenti adeguati dei fattori circostanti dall ar...

Страница 18: ...olare in ci che riguarda ci che non indicato in questo manuale 3 3 Istruzioni di sicurezza per la pompa 1 Imparare a conoscere i controlli e l uso appropriato dell apparecchio 2 L utilizzo di questo p...

Страница 19: ...trezzo e gli accessori non siano danneggiati 4 2 Collegamento del tubo di scarico non fornito 1 Avvitare il raccordo 6 fornito sul gomito di uscita della pompa Fig 1 2 Inserire il tubo di scarico sull...

Страница 20: ...ompa per pi di 24 ore La pompa sommersa deve obbligatoriamente essere immersa prima de avviarla Installare la pompa nell acqua quindi lasciar il tempo di evacuare l aria bolle d aria e soltanto dopo p...

Страница 21: ...ante sopra Assenza di flusso fori di aspirazione ostruiti Tubo di scarico piegato Pulire i fori di aspirazione Riposizionare il tubo correttamente La pompa non si arresta Il galleggiante non si affond...