36
POINT B - SETTINGS
DIP 1 (ON) BARRIER SLOWSPEEDS ADJUSTMENT IN OPENING AND CLOSING (ON) (See Point C)
DIP 1-2 STORING/ERASING RADIO CODES FOR MOTOR CONTROL (See Point D)
DIP 1-2-3 STORING/ERASING STORING/ERASING for relay R-AUX command (point E)
DIP SWITCHES CONTROL
DIP 4
Single impulse command START and RADIO - step-by-step (ON) - automatic (OFF)
DIP 5
Enable radio system SUN (ON) - SUN-PRO (OFF)
DIP 6
NORMAL operation (OFF) - PARK operation (ON)
DIP 7
ON - photocells self-test ENABLED
DIP 8
OPEN 2 command operation in PARK mode
ON - OPEN 2 command is always enabled
OFF - OPEN 2 command works if there is no vehicle on the magnetic sensor connected
to the TLC input (Traffic light control contact opened).
DIP 9
Courtesy light management (OFF)
They work with 1 Relay card ACQ9080 or 3 Relay card ACQ9081 (If none of the optional cards is
connected, turn DIP9 to OFF).
Magnet management with 1-RELAY card ACQ9080 (ON)
DIP 10
Operation after black-out
ON - the boom arm automatically closes if not already closed.
OFF - the boom arm remains still on the point it was when blackout occurred
DIP 11
ON - 3-phase motor
OFF - 1-phase motor
DIP 12
OFF - Electromechanical limit switches welded on pc card
DIP 13
ON - Lamp with flashing light / OFF - Blinker operation with fixed power supply
MOTOR TYPE
DIP 14
DIP 15
DIP 16
NORMAL
OFF
OFF
ON
LED WARNINGS
DL1
PROG programming activated
(red)
DL2
Barrier opening
(green)
DL3
Barrier closing
(red)
DL4
Opening limit switch LSO
(green)
DL5
Closing limit switch LSC
(red)
DL6
STOP command (NC)
(red)
DL7
PHOTO 1 contact (NC)
(red)
DL8
PHOTO 2 contact (NC)
(red)
DL9
EDGE 1 contact (NC)
(red)
DL10
PROG and RADIO (on MOLEX connector) commands
(green)
DL11
TCA - automatic closure time enabled
(red)
DL12
Remotes programming enabled
(red/green)
DL13
P1 managed by APP
(blue)
OPEN 1
OPEN 1 command (to enter)
(green)
OPEN 2
OPEN 2 command (to exit)
(green)
CLOSE
CLOSE command (NO)
(green)
START
Single impulse command (NO)
(green)
B.I.O
Clock command (NO)
(green)
OK CLOSE Confirmation of closing command
(green)
TLC
Magnetic sensor control for traffic light control
(green)
PROBE
Engine room temperature sensor for heating the engine in particularly cold climates, up to -30
°C (connection to connector J3) code ACG4666.
ADJUSTMENTS
TRIMMER LOW SPEED OPEN and TRIMMER LOW SPEED CLOSE - Slow speed regulators in opening
and closing approach
Slow speed regulation is performed by acting on the LOW SPEED OPEN and LOW SPEED CLOSE
trimmers through which the output voltage across the motor is varied (turning it clockwise
increases the speed).
The deceleration is automatically determined by the limit switches at about 30° before
reaching the opening or closing limit switch.
TRIMMER TCA - Automatic closing time regulator
By factory not enabled and LED DL11 OFF (trimmer rotated completely counter-clockwise)
With this trimmer it is possible to adjust the waiting time before having automatic closing.
The automatic closing is obtained only with the barrier open as a result of the command given
by the opening commands and led DL11 ON (trimmer rotated clockwise to enable the feature).
The pause time can be adjusted from a minimum of 2 s to a maximum of 2 minutes.
R-AUX - AUXILIARY RELAY CONTACT (NO)
By default this relay is set as courtesy light (max 700 W - 3 A- 230 Vac) to operate 3 minutes at
each command, with time renewal at each command.
It is possible to activate the R-AUX contact by remote control by performing the memorization
procedure described in point E.
POINT C - BARRIER SLOWSPEEDS ADJUSTMENT IN OPENING AND CLOSING
This check is meant to facilitate the installer during the start-up of the system or for any other
future controls:
1 -
Turn DIP 1 to ON
, the red led DL1 starts blinking
2 -
Press the PROG button
and hold it (movement is now performed in “hold-to-run” mode,
open-stop-close-stop-open etc.). If the GREEN led DL2 is on, the boom arm opens. If the RED
led DL4 is on, the boom arm closes.
3 -
Carry out the slow-down speed calibration => Turn the LOW SPEED OPEN and LOW SPEED
CLOSE trimmer to minimum =>
Press the PROG button
and hold it => After 1 s of movement
the low speed will be enabled.
CAUTION: Check that the motor has enough force to move the boom both in opening and
closing. If not, increase the value set on the trimmers until the optimal operating
condition is reached.
CAUTION: In areas subject to particularly cold temperatures, turn the trimmers clockwise 5°
more than the normal value, or apply the optional probe (code ACG4666) to heat
the engine.
4 -
Turn DIP1 to OFF
=> the red LED DL1 turns OFF.
During Point C procedure the safety-strip and photocells are not enabled.
POINT D - PROGRAMMING RADIO CODES FOR OPENING (1000 CODES MAX) - with radio module
ACG8069
ATTENTION: before storing the radio codes, use DIP 5 to select which transmitters to use:
DIP 5 OFF
: SUN-PRO variable code transmitters can be memorized:
SUN-PRO 2CH 2-channel - red keys and white led cod. ACG6210
SUN-PRO 4CH 4-channel - red keys and white led cod. ACG6214
DIP 5 ON (By factory)
: You can store transmitters with fixed code SUN:
SUN 2CH 2-channel - blue keys and white led
cod. ACG6052
SUN 4CH 4-channel - blue keys and white led
cod. ACG6054
SUN CLONE 2CH 2-channel - blue keys and yellow led
cod. ACG6056
SUN CLONE 4CH 4-channel - blue keys and yellow led
cod. ACG6058
ATTENTION: it is not possible to memorize at the same time transmitters with fixed code and
transmitters with variable code.
Programming can be done only when the gate is stationary.
1 - First set
DIP 1 to ON
and then
DIP 2 to ON
. The LED DL12 flashes red for 10 s.
2 - Press the TRANSMITTER button (usually channel A) within the allotted 10 s. If the remote
is memorized properly LED DL12 blinks green and a buzzer tone confirms the correct
memorization. The 10 s for programming the codes are automatically renewed, with LED
DL12 which flashes red, in order to store the next transmitter.
3 - To finish programming, wait 10 s, or press the PROG button briefly. LED DL12 stops flashing.
4 - Re-set
DIP 1 to OFF
and
DIP 2 to OFF
.
ALL RADIO CODES FOR TOTAL OPENING CANCELLATION PROCEDURE
Cancellations can only be performed when gate is stationary.
1 - Set
DIP 1 to ON
and then
DIP 2 to ON
.
2 - LED DL12 flashes red for 10 s.
3 - Press and hold the PROG button for 5 s. Memory cancellation is indicated by two green
flashes of LED DL12 and 2 tones of the buzzer.
4 - LED DL12 flashes red again for 10 s and you can add new codes as shown above.
5 - Re-set
DIP 1 to OFF
and
DIP 2 to OFF
.
RADIO CODES MEMORY FULL INDICATOR (FOR TOTAL OPENING)
Indication is visible only when gate is stationary.
1 - Set
DIP 1 to ON
and then
DIP 2 to ON
.
2 - The LED DL12 flashes green 6 times when the memory is full (1000 codes). Now LED DL12
blinks red for 10 s enabling possible cancellation of all codes.
3 - Re-set
DIP 1 to OFF
and
DIP 2 to OFF
.
POINT E - PROGRAMMING RADIO CODES (FOR R-AUX RELAY) (1000 CODES MAX) - with radio
module ACG8069
* Remote control management can be enabled only by the RIB GATE app.
R-AUX normally works as a courtesy light for 3 minutes.
Through the RIB GATE app it is possible to configure the operation of this relay as desired.
Programming can be done only when the gate is stationary.
1 - Set
DIP 1 to ON
,
DIP 2 to ON
and then
DIP 3 to ON
. DL12 flashes orange for 10 s.
2 - Press the transmitter button (usually channel C) within the allotted 10 s. If the transmitter
G
B
Содержание NORMAL
Страница 17: ...17 I ...
Страница 43: ...43 G B ...