39
G
B
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
EVENT
BUZZER STATUS
FLASHER STATUS
DL1 LED STATUS
DIP 1 ON
(hold-to-run mode)
Or failure of a safety device
OFF
OFF
Flashes ON/OFF 250 ms
DIP 2 ON
(stroke programming)
OFF
OFF
Flashes ON/OFF 500 ms
Programming sequence stopped due to intervention of a safety
device
10 s tone with 2 s pause
OFF
On steady
EVENT
BUZZER STATUS
FLASHER STATUS
DL12 LED STATUS
No transmitter code entered
OFF
OFF
Flashes red/green
DIP 1 ON > DIP 2 ON
- transmitter code programming for full
opening
OFF
OFF
Flashes red for 10 s
DIP 1 ON > DIP 2 ON > DIP 3 ON
- transmitter code programming for
R-AUX relay
OFF
OFF
Flashes orange for 10 s
Correct transmitter codes programming for opening and R-AUX
relay
1 Tone
OFF
Turns green once
Remote control code not present in memory
OFF
OFF
Turns red once
Memory saturated by remote control codes (1000 codes saved)
OFF
OFF
Runs 6 green flashes
Radio code deletion for opening and R-AUX relay
2 Tones
OFF
Runs 2 green flashes
WARNING SIGNALS DURING OPERATION
EVENT
BUZZER STATUS
FLASHER STATUS
LED STATUS AND SIGNAL OUTPUT
Stop button pressed
OFF
OFF
Led DL6 turns OFF
Photocell intervention
1 Tone
OFF
Led DL7-8 turns OFF
Edge intervention
2 Tones
OFF
Led DL9 turns OFF
Failure of a safety device or safety device engaged for too long
OFF
OFF
Led DL1 flashes ON/OFF 250 ms
Alarm from edge
2 Tones every 5 s for 1 minute
(It is renewed by giving a command)
Flashes for 1 minute
No led combined
Failed photocells auto-test alarm
4 Tones every 5 s for 1 minute
(It is renewed by giving a command)
OFF
No led combined
Functional block activated by smartphone
OFF
OFF
Led DL12 is steady on green.
Achievement of set cycles
6 Tones every 5 s
(It is renewed by giving a command)
OFF
No leds matched
Energy saving activated by smartphone
OFF
OFF
Blue led flashes once every 5 s
Alarm - no limit switches reached or unlocked barrier
5 Tones
Flashes for 1 minute
No leds matched
FAULT
SOLUTION
After having carried out the various connections and having supplied voltage, all the LEDS are
switched OFF.
On the board there are resettable fuses which intervene in the event of a short circuit,
interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable connectors and
insert them one at a time in order to more easily identify the cause of the fault.
Check the integrity of fuse F1.
In case of interrupted fuse use only of adequate value
F1 = T 5A Fuse for motor protection
The motor opens and closes, but it has no strength and moves slowly.
Check trimmers LOW SPEED OPEN and LOW SPEED CLOSE adjustment.
The gate opens but does not close after the time set.
Make sure that the TCA trimmer is activated with LED DL11 ON.
B.I.O. contact always on / green led on => check the status of the clock connected to B.I.O.
input.
Photocells Auto-test failed => check the connections between the control panel and the
photocells.
The gate does not close by activating the various START, RADIO and CLOSE buttons.
Faulty safety edge contact. Faulty photocells contact => Fix or replace the faulty contact.
Photocells Auto-test failed => check the connections between the control panel and the
photocells.
By activating the START, OPEN or CLOSE button the barrier does not move.
START, OPEN or CLOSE command always active.
Check and replace any buttons or micro-switches of the selector switch.
The slowing phase is not performed.
Check LOW SPEED OPEN e LOW SPEED CLOSE trimmers adjustment.