18
18
G
B
Secondary transformer connector
Radio antenna
Common contact unit
Photocell contact (NC)
Stop opening limit switch M1 (NC)
Stop closing limit switch M1 (NC)
Stop opening limit switch contact M2 (NC)
Stop closing limit switch contact M2 (NC)
Stop button contact (NC)
Opening button contact (NO)
Closing button contact (NO)
Single pulse contact (NO)
Accessory power supply at 24Vac
Gate open light 12Vdc
Wiring acoustic warning (12Vdc max 200 mA)
Electric lock connection (Max 15W 12V)
MOTOR 2 COMMON CONNECTION UNIT
MOTOR 2 INVERTER AND CAPACITOR
CONNECTION
MOTOR 1 COMMON CONNECTION UNIT
MOTOR 1 INVERTER AND CAPACITOR
CONNECTION
BLINKER (max 40W )
Power supply 230Vac 50/60Hz (on request
120V/60Hz)
Connector for transformer primary connection
Connector for heater supply board (Optional -
DO NOT TOUCH THE GUARD!
)
Terminal board for Encoder M1 and M2
connection
Encoder M1 signal
Encoder M1 power positive sign
Encoder M1 and M2 power negative sign
Encoder M2 power positive sign
Encoder M2 signal
Connector for EXPANDER board
Connector for 24Vac radio receiver
Connector for heater board control
DO NOT TOUCH THE JUMPER !
IF IT IS REMOVED THE OPERATOR
DOESN’T MOVE !
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
SEC.TRANSF.
AERIAL
COM
PHOT.1 NC
LSO
LSC
LSO
LSC
STOP
OPEN
CLOSE
K BUTT.
A*A
SIGNAL
BUZZER
LOCK
U - MOTOR 2
V-W - MOTOR 2
U - MOTOR 1
V-W - MOTOR 1
L1 - N
PRI.TRANSF.
HEATER SUPPLY
ENCODER
S-M1
+ M1
GND
+ M2
S-M2
EXP.
RADIO
HEATER
A -
CONNEXIONS
NOTE: IF THE ELECTRIC LIMIT SWITCHES ARE NOT USED, THERE IS
NO NEED TO BYPASS THEM OUT WITH A JUMPER. THEY CAN
BE BYPASSED IF JUMPER S3 IS OPEN.