53
MOTOR EARTH
LINE EARTH
J3
J1
J12
S1
TF
J7
J6
J2
JP
1 - 2
J4
VR2
J8
J9
J5
J11
VR1
J10
ON
1 2 3 4 5 6 7
8
15
16
1
11
12
13
14
2
3
4
5
7 6
8
9
10
17
18
22
23
24
19
20
21
G
B
J1
L-N
230Vac 50/60Hz power supply
J2
1
Single pulse contact (NA) K
2
Common to contacts
3
Contact for photocells (NC)
4
Common to contacts
5
Facet contact (NC) - for opening and closing interventions
6
Common to contacts
7
Common to contacts
8
A* TEST - 24 Vac facet auto-test power
9
A* - 24Vac accessory power
10
A - 24Vac common accessory power
J3
11
Flashing lamp power supply (24 Vdc)
12
Not connected
13
K Cover single pulse contact (NA) on flashing lamp
14
Common to contacts
J4
15
Antenna cable earthing
16
Antenna cable central wire
J5
17
18
Signal light 230V40 W max
J6
19 V1
MASTER opening phase motor
20 U1
Common MASTER motor
21 W1
MASTER closing phase motor
J7
22 V2
SLAVE opening phase motor
23 U2
Common SLAVE motor
24 W2
SLAVE closing phase motor
J8
CAP
Connector for MASTER motor condenser
J9
LSC
Contact for closing stop limit switch
LSO
Contact for opening stop limit switch
COM
Common to contacts
J10
ENCODER S
Connector for encoder - green wire (signal)
E
Connector for encoder - brown wire (+ 5 v)
ENCODER -
Connector for encoder - white wire (earthing)
J11
RADIO
Built-in radio module
J12
DO NOT TOUCH THE JUMPER! THE OPERATOR IS
DISABLED IF THE JUMPER IS REMOVED!
VR1
TRIMMER TCA
Trimmer for automatic closing time adjustment. DISABLED
DEFAULT AND DL9 LED OFF
VR2
TRIMMER
TORQUE
Trimmer with force electronic regulation
JP1
Activation of radio code clearing
JP2
Encoder enabling with crush prevention safety (active if
closed)
P1
S1-PROG.
Programming control lever
F1
T 5A
Fuse to protect network and motor power
F2
T 0,1A
Fuse to protect secondary circuit
A - CONNEXIONS