code ACG9447
ATTENTION:
CONNECT MAX 2 KEYPADS
IN THE CARD - B -
(to connect in parallel).
ATTENTION:
to do programming procedure
connect only 1 KEYPAD in the
card - B -.
TURN OFF POWER SUPPLY
BEFORE YOU INSERT THE
CARD
WIRED KEYPAD - CONNECTIONS AND PROGRAMMING
FOR SLIDER AUTOMATIC DOORS
channel A
- C -
W
IRED KEYPAD PROGRAMMING
- Remove cover - A - from control panel.
- Insert card - B - cod. ACG9447 in one of the free places.
- Turn on control panel power supply.
- Press and maintain pressed button - C -. You have 5 seconds to digit the
code (min. 4 / max 9 numbers) and confirm pressing button
A
. You hear
a “BEEP” to confirm the record of the new code.
- Release button - C - .
- Repeat these steps for every new code to record.
- Close cover of the control panel - A -.
S
IGNALS
no “BEEP”s
= code to record.
1 “BEEP”
= code recorded.
2 “BEEP”
= if code is already present in the memory.
3 “BEEP”
= after deletion of one code.
4 “BEEP”
= during deleting procedure. Code not present in
memory.
5 “BEEP”
= memory full (max 125 codes).
10 “BEEP”
= All codes deleted.
DELETING ONE CODE
Press and maintain pressed button - C - up to obtain a permanent
“BEEP”.
Digit the code to delete (3 “BEEP” follows to confirm deletion).
Release button - C -.
DELETE ALL CODES
Press and maintain pressed button - C - up to when permanent
BEEEP stops. (10 “BEEP”s follow to confirm total deletion).
Release button - C -.
Wired Keypad has backlighted buttons.