22
1 - JOLLY BIG operator
2 - Photoelectric cells (external)
3 - Push-Button
4 - Key selector
5 - Tuned aerial
6 - Flashing lamp
IN ORDER TO ENSURE A CORRECT FUNCTION ONLY RIB’S COMPONENTS
MUST BE USED
Measurements in mm/in
Ø 245/9,6
382/15
TECHNICAL DATA
JOLLY BIG ONE
JOLLY BIG TWO
Electric motors
N°
1
2
Max gate weight
kg/lbs
280/617
450/992
Max gate surface
m
2
24
30
Limit switch winding capacity
N. rotat.
7,5
Nominal functioning torque
Nm
240
480
Max operating torque
Nm
180
340
Max lifting force from earth
kg/lbs
200/440
440/880
Max operating force
kg/lbs
160/352
290/638
Pulley revolutions
rpm
8 (50Hz) - 9,7 (60Hz)
Pulley diameter
mm/in
240/9,456 - 280/11,032 with adapter ACJ9059
Shaft diameter
mm/in
102/4,012 - 76/2,994 with adapter ACJ9058
EEC Power supply
230V ~ 50-60Hz
Motor capacity with load
W
570 (50Hz) - 550 (60Hz)
1140 (50Hz) - 1100 (60Hz)
Power absorbed with load
A
2,7 (50Hz) - 2,6 (60Hz)
5,3 (50Hz) - 5,2 (60Hz)
Capacitor
µF
20
40
Functioning cycles
N.
4 - 20s/2s
Daily operations suggested
N.
20
Service
30%
Nominal functioning time
s
180
Motor weight
kg/lbs
11/24,2
16,5/36,3
Working Temperature
°C
-10 ÷ +55
Protection
IP
30
G
B
TECHNICAL DATA / INSTALLATION JOLLY BIG
ROLLING GATE CONTROL
The European Standard EN 12604 “Industrial, Commercial and Garage Doors and Gates -
Mechanical Aspects - Requirements”, at the point 4.3. “Protection against unintentional and
uncontrolled movements” requires also that*:
a - The vertically operating door leaves shall be balanced so that the door leaf can stop in
any position, or that the out-of-balance state shall not produce, in any case, a static
force at the primary closing edge of the door exceeding 150N (15,3 kg / 33,70 lbs).
Verify it after having manually released the JOLLY BIG operator.
b - If a spring fails, the resulting out-of-balance static force occurring at the primary
closing edge of the roller shutter shall not exceed 200N (20,4 kg / 44,94 lbs), even
when the Jolly operator is manually released. After this failure, you must intervene on
the door to substitute the broken spring and correct the balance state. Therefore, we
suggest you to fraction the roller shutter weight with an adequate number of springs
(* This is a free interpretation).
WARNING: The EN 12453 standard “Industrial, commercial and garage doors and gates
- safety in use of power operated doors - test methods” at point 6.2.2 “safeguarding
against hazard of being lifted” provides that the rolling gate shall not be able to lift more
than 20 kg / 44 lbs. In order to meet this standard, RIB suggests to install the control
board with electric power regulation J-CRX (cod. ABJ7080).
Parts to install according to EN 12453 standard
COMMAND TYPE
USE OF THE SHUTTER
Skilled persons
(out of public area*)
Skilled persons
(public area)
Not skilled
persons
Hold-to-run operation
A
B
Not possible
Impulsive - in sight
(e.g. push-button)
C or E
C or E
C and D, or E
impulsive - out of sight
(e.g. remote)
C or E
C and D, or E
C and D, or E
automatic
C and D, or E
C and D, or E
C and D, or E
* a typical example are those doors which do not have access to any public way
A: Hold-to-run operation made by push-button ex: code ACG2013
B: Hold-to-run operation made by key selector ex: code ACG1010
C: Adjustable power of the motor or photocells to respect impact forces as indicated in
Annex A
D: Safety strips and/or other additional devices to reduce the probability of contact with
the door.
E: Devices installed in such a way that a person can not be touched by the door.