Chapter 2 Installation and Confirmation
39
2
Three-Phase 400V Series
Model number
RM6F5-____
Input
Current
(A)
MCCB
(A)
Input wire size
(R/L1,S/L2,T/L3)
(mm²)
Control circuit
wire size
(mm²)
Grounding
wire size
(mm²)
4001
3
5
2.0
0.75~1.25
2.0
4002
4.2
10
2.0
2.0
4003
5.8
15
2.0
2.0
4005
9.6
20
3.5
3.5
4007
13
30
3.5
3.5
4010
20
30
5.5
5.5
4015
25
40
8.0
8.0
4020
38
75
8.0
8.0
4025
42
75
14
14
4030
52
100
22
22
4040
64
125
22
22
4050
84
150
22
22
4060
100
175
38
38
4075
130
200
60
60
4100
155
250
80
80
4125
177
300
100
100
4150
196
300
60*2
60*2
4175
217
350
100*2
100*2
4200
282
400
100*2
100*2
4250
355
600
150*2
150*2
4300
385
600
200*2
200*2
4350
440
700
250*2
250*2
4420
540
800
250*2
250*2
4500
650
1000
325*2
325*2
4600
800
1200
325*2
325*2
4700
900
1200
325*2
325*2
Cautions:
i. Please refer to the local electrical code with respect to the wiring(the loading
and continuity, the wire capability for the current and temperature, the length of
wiring, and the surrounding temperature must be all considered in order to add
or reduce the size of the wire).
ii. Please use the cable that is suitable for 600V, 75
℃
above.
iii. This table is only for reference.