39
Section I :: User
EN
A table with shielded cables recommended according to the several
installations is provided below. The indicated Belden codes meet the
specifications required; cables of other manufacturers can be used
provided that the specifications below are complied with.
(*)
Recommended type of shielded cable
INSTALLING THE SERIAL BOARD ON UNIT BOARD
Compact-Y / Mini-Y / Comby-Flow range
Z-Power / Z-Flow range
Z-Power / Y-Power / Y-Flow bicircuiot / EXP range
Y-Pack range
Serial Card
3 2 1
1
GND
2
RX+/TX+
3
RX-/TX-
Section
(AWG)
Section
(mm2)
Cable
resistance
(Ω/km)
Cable max
length (m)
Belden
Code (*)
16
1,50
13,7
1173
9860
18
1,00
22,6
711
3074F
22
0,50
48,2
333
3105°
24
0,22
78,7
204
9841 o 8103
Cable impedance: 120 Ohm (essential characteristic).
Parasite capacity: about 40 pf/mt (optional characteristic).
Signal propagation time: 5 ns/mt (optional characteristic).
Depending on the estimated length of the network, the cable with lower
section can be used. For example, a AWG 22 cable is sufficient for a
maximum length of 300 m.
(*)
Note: an AWG 20/22 shielded cable (4 wires + shield) and two
branching boards (use the E968573484 KIT) must be used to connect
the terminal and sequencer when the length exceeds 50 m and reaches
a maximum of 200 m. As shown in the diagram below.
Follow these guidelines to connect the Sequencer Terminal:
Main characteristics of the serial cable to be used
Sequencer terminal connection
o
Use a 6-wire telephone cable and RJ12 connectors;
o
terminate the cable as shown in the figures;
o
the cable length must not exceed 50m (*).
Bianco White Blanc Weiss Blanco
Nero Black Noir Schwarz Negro
Rosso Red Rouge Rot Rojo
Verde Green Vert Gren Verde
Giallo Yellow Jaune Gelb Amarillo
Blu Blue Bleu Blau Azul marino
1
2
3
4
5
6
1 Rx/Tx-
2 Rx/Tx+
3 GND
4
5
6
Содержание KMSR
Страница 91: ...91...