12
RAYPAK, INC.
NOTES GÉNÉRALES:
EXIGENCES DE PRESSION PROPRES AU SITE, SELON ASCE 7-10 ET CHAPITRE 16
DU CODE DU BÂTIMENT DE LA FLORIDE; DOIVENT ÊTRE INFÉRIEURES OU
ÉGALES AUX PRESSIONS NOMINALES INDIQUÉES ICI POUR TOUT ASSEMBLAGE
TEL QU’INDIQUÉ. EXIGENCES DE PRESSION DE CONCEPTION DOIVENT ÊTRE
DÉTERMINÉES PAR UN CONCEPTEUR PROFESSIONNEL SELON LE PROJET,
CONFORMÉMENT AU CODE APPLICABLE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
CE SYSTÈME EST CONÇU ET FABRIQUÉ CONFORMÉMENT AUX EXIGENCES
DU CODE DU BÂTIMENT DE LA FLORIDE SIXIÈME ÉDITION (2017). CE SYSTÈME
PEUT ÊTRE UTILISÉ À L’INTÉRIEUR ET À L’EXTÉRIEUR DE LA ZONE
CYCLONIQUE. CE PLAN N’EST PAS DESTINÉE À CERTIFIER LA RÉSISTANCE
AUX CHOCS DE L’ARMOIRE DE L’UNITÉ MÉCANIQUE.
AUCUNE AUGMENTATION DE 33-1/3% DU STRESS ADMISSIBLE N’A ÉTÉ
UTILISÉE DANS LA CONCEPTION DE CE SYSTÈME.
TOUTES LES DIMENSIONS ET LE POIDS MINIMAL (100 LB MIN.) DE L’UNITÉ
MÉCANIQUE DOIVENT ÊTRE CONFORMES AUX LIMITES DU PRÉSENT
DOCUMENT. TOUTES LES SPÉCIFICATIONS MÉCANIQUES (DÉGAGEMENTS,
TONNAGE, ETC.) DOIT ÊTRE CONFORME AUX RECOMMANDATIONS DU
FABRICANT ET RELÈVENT EXPRESSÉMENT DE LA RESPONSABILITÉ DE
L’ENTREPRENEUR.
LES ANCRAGES INDIQUÉS AUX PRÉSENTES: ELCO ULTRACON SS4 OU
L’ÉQUIVALENT, INSÉRÉ DANS DU BÉTON 3000 PSI MIN. VOIR NORMES
D’ANCRAGE CI-CONTRE. TOUS LES ANCRAGES DOIVENT ÊTRE PROTÉGÉS
CONTRE LA CORROSION GALVANIQUE.
LE BÉTON SPÉCIFIÉ AUX PRÉSENTES N’EST PAS CERTIFIÉ. AU MINIMUM, LE
BÉTON STRUCTURAL DOIT AVOIR UNE ÉPAISSEUR DE 4 PO ET UNE
RÉSISTANCE À LA COMPRESSION MINIMALE DE 3000 PSI, SAUF INDICATION
CONTRAIRE. THICK AND SHALL HAVE MINIMUM COMPRESSIVE STRENGTH OF
3000 PSI, UNLESS NOTED OTHERWISE.
L’ENTREPRENEUR DOIT ISOLER TOUS LES MATÉRIAUX DIFFÉRENTS AFIN DE
PRÉVENIR LA CORROSION GALVANIQUE.
MALT, SI REQUIS, N’EST PAS SPÉCIFIÉ AUX PRÉSENTES ET N’EST PAS
FOURNI.
LA CAPACITÉ DE TOUTE STRUCTURE À RÉSISTER AUX CHARGES COMBINÉES
DOIT ÊTRE VÉRIFIÉE PAR UN PROFESSIONNEL DE LA CONCEPTION ET N’EST
PAS INCLUSE À LA PRÉSENTE CERTIFICATION. SAUF INDICATION EXPRESSE,
AUCUNE CERTIFICATION SUPPLÉMENTAIRE N’EST SPÉCIFIÉE AUX
PRÉSENTES.
LE SYSTÈME DÉTAILLÉ REPRÉSENTE UNE INSTALLATION GÉNÉRIQUE ET NE
FOURNIT PAS D’INFORMATION POUR UN SITE PARTICULIER. SI LES
CONDITIONS DU SITE DIFFÈRENT DES CONDITIONS DÉCRITES AUX
PRÉSENTES, UN INGÉNIEUR AGRÉÉ DOIT PRÉPARER DES DOCUMENTS DE
SITE PARTICULIER EN VUE DE LEUR UTILISATION EN CONJONCTION AVEC LE
PRÉSENT DOCUMENT.
NOTES DE CONCEPTION:
NORMES D’ANCRAGE
BÉTON:
(4” ÉPAISSEUR MIN.,
3000 PSI MIN.)
SUBSTRAT
DESCRIPTION
CROSSWIND-30-I
23.23"
DIMENSIONS et MODÈLES:
CRITÈRES DE CONCEPTION APPROUVÉS:
50,2 PSF LATÉRAL;
41,2 PSF
SOULÈVEMENT
ESTIMATION DE LA CHARGE DE VENT DES MODÈLES CROSSWIND: AU NIVEAU DU SOL
(1)-1/4"Ø ELCO ULTRACON SS4, 1,75" BÉTON 3 KSI; 2,5" MIN. DE LA BORDURE; 3" MIN. DE TOUT ANCRAGE ADJASCENT, OU ANCRAGE
ÉQUIVALENT.
UNITÉ MÉCANIQUE
VUE ISOMÉTRIQUE
Modèles
"A"
"B"
"C"
"D"
23.23"
23.23"
23.23"
12.40"
12.40"
12.40"
15.55"
13.39"
37.83"
13.39"
13.39"
16.54"
37.83"
37.83"
37.83"
"E"
25.91"
"F"
12.29"
POIDS
101 LBS
25.91"
25.91"
25.91"
12.29"
12.29"
15.35"
126 LBS
150 LBS
172 LBS
UNITÉ MÉCANIQUE
BASE EN BÉTON (NON FOURNIE)
CROSSWIND-40-I
CROSSWIND-50-I
CROSSWIND-65-I
BALAYER ICI
:
OU, ALLER À ECALC.IO/TER
À PROPOS DE CE DOCUMENT
LES ORIGINAUX, LES VERSIONS ET PLUS
D’INFORMATIONS CERTIFIÉES AU
ENGINEERINGEXPRESS.COM/STORE, OU
BALAYER CETTE ADRESSE >
DOCUMENT NON VALIDE SANS LA CERTIFICATION
ORIGINALE DE L’INGÉNIEUR
BASE EN BÉTON (NON FOURNIE)
UNITÉ MÉCANIQUE
VUE AVANT
VUE AVANT
"D"
"E"
"F"
"E"
UNITÉ MÉCANIQUE
UNITÉ MÉCANIQUE (VOIR MODÈLE DANS TABLEAU)
Pas à l’échelle
Pas à l’échelle
Pas à l’échelle
Pas à l’échelle
ÉLÉVATION
DÉTAIL ATTACHE
RAIL BASE DE L’UNITÉ
UNITÉ MÉCANIQUE
BASE EN BÉTON (NON FOURNIE)
VOIR NORMES D’ANCRAGES À BÉTON POUR LA SÉLECTION
UNITÉ MÉCANIQUE
Pas à l’échelle
ATTACHES
PLAN
"B"
"A"
"C"
"D"
Figure 10. Arrimage des sangles anti-ouragans
Voir "T
ableau C. Dimensions - po (mm)" à la
page 10 pour les dimensions poids.
Содержание Raypak CROSSWIND-30-I
Страница 14: ...14 5 WIRING DIAGRAMS Crosswind 30 I 50 I Touch Controller...
Страница 15: ...15 Crosswind 40 I Touch Controller...
Страница 16: ...16 Crosswind 65 I Touch Controller...
Страница 17: ...17 LED Controller Automation Controller Crosswind 40 O...
Страница 18: ...18 LED Controller Automation Controller Crosswind 50 O...
Страница 19: ...19 LED Controller Automation Controller Crosswind 65 O...
Страница 33: ...33 NOTES...
Страница 34: ...Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 www raypak com www raypak com...
Страница 67: ...33 NOTES...
Страница 68: ...Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 www raypak com www raypak com...