Lighting the Water Heater

 

Before operating this water heater, be sure to read and follow the instructions on the label pictured 

below and all other labels on the water heater, as well as the warnings printed in this manual. Failure 

to do so can result in unsafe operation of the water heater resulting in property damage, personal 

injury, or death.  Should you have any problems reading or following the instructions in this manual, 

STOP, and get help from a qualified person.

FOR YOUR SAFETY READ BEFORE OPERATING

OPERATING INSTRUCTIONS

TO TURN GAS OFF TO THE APPLIANCE

WARNING:

If you do not follow these instructions and the Use & Care

 

Manual instructions exactly, a fire or explosion may result causing property 

damage, personal injury or loss of life.

If you cannot reach your gas 

supplier, call the fire department.

 

 

C.

Do not use this appliance if any part has 

been under water. Immediately call a 

qualified installer or service agency to 

replace a flooded water heater. Do not 

attempt to repair the unit! It must be 

replaced!

Use only your hand to push in the gas 

control buttons. Never use tools. If the 

control buttons will not push in, don’t try 

to repair them, call a qualified service 

technician. Force or attempted repair 

may result in fire or explosion.

D.

gas supplier’s instructions.

10.

11.

1.

2.
3.

VACATION

WARNING

VERY

HOT

WARM

A

B

C

COOLER

HOTTER

This appliance does not have a pilot. It is 

equipped with an ignition device which auto-

matically lights the burner. 

Do NOT try to light 

the burner by hand.

A.

BEFORE PUTTING THIS APPLIANCE INTO 

SERVICE - Smell all around the appliance 

area for gas. Be sure to smell next to the 

floor because some gas is heavier than air 

and will settle on the floor.

 

B.

Immediately call your gas supplier 

from a neighbor’s phone. Follow the 

Do not try to light any appliance.

Do not touch any electric switch; do 

not use any phone in your building.

WHAT TO DO IF YOU SMELL GAS

Turn off all electrical power to the appliance.

Set the thermostat to the lowest setting by first depressing the COOLER       and HOTTER       

     buttons at the same time and holding for (1) second.  Depress the COOLER       button 

until only the WARM indicator light is lit.

Stop!  Read the safety information above 

on this label.

Toggle the “ON/OFF” switch located on the 

blower assembly to the “OFF” position.

Turn off all electrical power to the appliance.
This appliance is equipped with a Hot 

Surface Ignition System which auto-

matically lights the burner. 

Do NOT open 

the inner door of this appliance and try to 

light the burner by hand!

Wait five (5) minutes to clear out any gas.  

If you smell gas, STOP!  Follow “B” in the 

safety information above on this label.  If 

you do not smell gas, go ahead to the next step.

Turn on all electrical power to the appliance.
Toggle the “ON/OFF” switch located on the 

blower assembly to the “ON” position.
Set thermostat to the desired temperature

setting by pressing the COOLER       and

HOTTER       buttons at the same time and

holding them for (1) second. Depress the

HOTTER       button until the desired 

temperature display setting is lit. The 

preferred starting point for temperature 

setting is indicated by     on the thermostat.
If the appliance will not operate, follow 

the instructions “TO TURN OFF GAS TO 

APPLIANCE” and call your service 

technician or gas supplier.

1.

4.

3.

5.
6.

7.

8.
9.


Set the thermostat to the lowest setting 

by pressing the COOLER       and HOTTER      

      buttons at the same time and holding 

them for (1) second. Depress the COOLER

      button until only the WARM indicator 

light is lit.

  

Toggle the “ON/OFF” switch located on the blower assembly to the “OFF” position.

Toggle the “ON/OFF” switch located on the 

blower assembly to the “ON” position.

2.

Содержание Power Direct Vent Series

Страница 1: ...s for the proper installation and adjustment of the water heater and two for the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater...

Страница 2: ...can save you time and money over the life of your water heater You ll find many answers to common problems in the Troubleshooting Guide If you review the chart of Troubleshooting Tips first you may n...

Страница 3: ...int thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible materials anywhere near or in the vicinity of a water heater...

Страница 4: ...water temperature for each LED indicator of the Combination Gas Control s display D A N G E R HOT Water temperature over 125 can cause severe burns instantly or death from scalds Children disabled an...

Страница 5: ...LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to look...

Страница 6: ...has been subjected to overheating fire flood physical damage or if the gas supply fails to shut off Read this manual entirely before installing or operating the water heater Use this appliance only f...

Страница 7: ...ids which give off flammable vapors are to be used or stored Such liquids include gasoline LP gas butane or propane paint or adhesives thinners solvents and or combustible removers DO NOT obstruct or...

Страница 8: ...ushion built in that compresses as the system pressure increases thereby relieving the over pressure condition and eliminating the repeated operation of the relief valve Other methods of controlling t...

Страница 9: ...relief valve above a suitable open drain to eliminate potential water damage Piping used should be of a type approved for hot water distribution The discharge line must be no smaller than the outlet...

Страница 10: ...e compound is used as the valve body may be damaged The inlet gas pressure to the water heater must not exceed 14 0 in w c 3 5 kPa w c for natural gas or 14 0 in w c 3 5 kPa w c for LP gas For purpose...

Страница 11: ...ABS Schedule 40 DWV Cellular Core ASTM F628 This water heater is approved to use the following materials for the fittings of the vent and combustion air intake systems PVC Schedule 40 DWV ASTM D2665...

Страница 12: ...the instructions in this manual before completing the installation and putting the water heater into service Connect the vent system piping to the blower assembly using the already installed 2 in 5 1...

Страница 13: ...e same atmospheric pressure zone The minimum and maximum equivalent lengths for the vent and combustion air inlet systems are shown in Table 1 Maintain a minimum vertical height of 1 foot 3 5 cm of pi...

Страница 14: ...alent Vent Combustion Air Inlet Lengths Each Pipe Run Max Allowed Equivalent Vent Combustion Air Inlet Lengths Each Pipe Run Vent and Combustion Air Inlet System Termination s Inches Feet Meters Feet...

Страница 15: ...re firmly tight then leak test the vent sys tem joints using a soap and water solution Repair any leak before allowing the water heater to oper ate When using CPVC or ABS pipe and fittings use 90 elbo...

Страница 16: ...ows 75 Gallon 75 100 70 000 Btu hr Models 3 8 2 5 50 15 90 Elbows 3 8 2 5 40 12 Concentric 4 8 2 5 100 30 90 Elbows From 2 000 Ft 609 m Above Sea Level through 5 999 Ft 1 828 m Above Sea Level Model V...

Страница 17: ...bows 3 7 2 45 13 5 Concentric 4 7 2 100 30 90 Elbows 65 Gallon 65 000 56 000 Btu hr Models 4 8 3 50 15 90 Elbows 75 Gallon 75 100 70 000 Btu hr Models 4 8 3 50 15 90 Elbows From 7 701 Ft 2347 m Above...

Страница 18: ...to inside corner H Clearance to each side of centerline extend ed above meter regulator assembly I Clearance to service regulator vent outlet J Clearance to nonmechanical air supply inlet to building...

Страница 19: ...ctors in equivalent vent and or combus tion air inlet lengths longer than 8 feet 2 44 meters or on any other Power Direct Vent model Additional Considerations Do Not install the vent terminal under an...

Страница 20: ...it to the vent connector fitting on the water heater s blower assembly Horizontal lengths of the vent system must slope downward away from the water heater a minimum of 1 8 in per foot 10 mm per meter...

Страница 21: ...ed downward Support vertical and horizontal lengths of the vent and combustion air inlet systems as previously mentioned Vent Connections Figure 5 Combustion Air Inlet Connection Vent Connections Comb...

Страница 22: ...warnings on material containers CAUTION For proper installation DO NOT use solvent cement that has become curdled lumpy or thickened DO NOT thin solvent cement Observe shelf precautions printed on th...

Страница 23: ...ALLUMAGE DE REMPLACEMENT DOIT TRE TALONN 250 C IGNITER AND FLAME SENSOR ALLUMEUR ET CAPTEUR DE FLAMME FLAMMABLE VAPOR SENSOR D TECTEUR DE VAPEUR INFLAMMABLE H G N 120 VAC PLUG FOR POWERVENT BLOWER ASS...

Страница 24: ...any responsibility for such loss or injury resulting from the use of such unau thorized devices CAUTION If local codes require the application of an external insulation blanket to this water heater p...

Страница 25: ...techni cian A new burner access door gasket must be installed on any burner access door that has been removed DON T install this water heater where standing water may occur The base of the water heat...

Страница 26: ...ed Soap and water solution used to check all con nections and fittings for possible gas leak GasCompanyinspectedinstallation ifrequired D Relief Valve Temperature and Pressure Relief Valve properly in...

Страница 27: ...Installation Spring loaded check valve in heating unit hot water supply line and cold water return line not supplied with water heater NOTE This check valve is incorporated in some heating units Refer...

Страница 28: ...all your gas supplier from a neighbor s phone Follow the Do not try to light any appliance Do not touch any electric switch do not use any phone in your building WHAT TO DO IF YOU SMELL GAS Turn off a...

Страница 29: ...ting The temperature of the water in the water heater can be regulated by pressing the buttons on the front of the gas control thermostat Safety and energy conservation are factors to be considered wh...

Страница 30: ...trol thermostat Therefore always remember to test the water temperature with your hand before use and remember that hotter water increases the risk of scald injury Also always supervise young children...

Страница 31: ...in gas valve which will extinguish the main burner flames The blower motor will stay energized for an additional 30 seconds after the control verifies that the burner flame is extinguished in order to...

Страница 32: ...es periodically this may be due to ther mal expansion in a closed water system Contact the water supplier or your plumb ing contractor on how to correct this DO NOT plug the relief valve outlet A wate...

Страница 33: ...ssembly Inspect the combustion air inlet and vent systems Make certain that all joints are secure and that combustion air inlet and vent system supports are all in place Check the outdoor combustion a...

Страница 34: ...combustion air inlet systems Unable to light the main burner Air in gas line Contact a qualified service techni cian to purge the air from the gas line Blocked vent system Contact a qualified service...

Страница 35: ...ow to correct this Do not plug the relief valve outlet Not enough or no hot water Water usage may have exceeded the capacity of the water heater Wait for the water heater to recover after an abnormal...

Страница 36: ...t surface ignitor A B C System in lockout 1 Gas supply is off or too low to operate Turn on the gas supply and or increase the inlet gas supply pres sure 2 Hot surface ignitor not positioned correctly...

Страница 37: ...ing gas control thermostat burners vent connectors or other safety devices Refer repairs to qualified service personnel Use only original equipment replacement parts Blower Assembly Flue Baffle Anode...

Страница 38: ...38 Notes...

Страница 39: ...39 Notes...

Страница 40: ...tic the hard wired carbon monoxide detec tor with alarm and battery back up may be installed on the next adjacent floor level b In the event that the requirements of this subdivision can not be met at...

Отзывы: