![Rheem Multipak MPE02 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/rheem/multipak-mpe02/multipak-mpe02_owners-manual-and-installation-instructions_1452124033.webp)
INSTALLATION – WATER HEATER
33
HORIZONTAL FLUE INSTALLATION
Horizontal Flueing – Directly Behind Water Heater
This method of flue installation is used where the secondary flue is to penetrate and terminate immediately
behind the wall on which the water heater is mounted.
Do not remove the plastic film from the flue outlet of water heater prior to this type of flue installation, to prevent
debris from the drilling operation entering the water heater flue outlet.
Notes:
Ensure each flue component is fully engaged and the rubber seal on the inner duct is well seated at each joint.
Each flue component is supplied with screws to connect to the adjacent flue component. The screws are
located in a bag taped to the outside of the flue component.
1.
Carefully remove the template inserted as the middle pages of this installation instructions booklet.
2.
Align the mounting bracket holes on the template exactly over
the upper wall mounting bracket holes on the water heater.
This step presumes the water heater is hung on the wall. For floor
mounted units, align the template as close as possible with the
upper mounting bracket holes on the water heater.
It may be convenient to tape the template to the wall.
Note:
Ensure there are no studs, noggins, pipes or electrical
cables located in the wall where the flue is to penetrate
3.
Mark the pilot hole location through the centre of the template.
Remove but
DO NOT DISCARD
the template, repeat for
each water heater.
4.
Drill a pilot hole using a 6.5 mm diameter or smaller drill bit.
The drill bit must be long enough to penetrate completely through
the outer skin of the external wall.
Note:
Ensure the drill remains level and straight during this step.
5.
Cut along the middle of the
bold
circle marked “Cut Line” on the template.
6.
Align the centre of the template with the pilot hole on the wall surface and scribe around the template onto
the wall.
The circle should be 150 mm in diameter.
Remove but
DO NOT DISCARD
the template, repeat for each water heater.
7.
Align the centre of the template with the pilot hole on the outside wall surface and scribe around the
template onto the wall.
The circle should be 150 mm in diameter.
Remove the template.
8.
Drill or cut the flue termination hole through the wall using a cutting tool suitable for the wall construction.
Note:
The Trim Ring (PN 295125) will cover a 150 mm diameter hole.
Position template
Содержание Multipak MPE02