Trouble Shooting Guide

** For your safety, DO NOT attempt repair of Electrical Wiring, Thermostat(s), Heating Elements or other Operating Controls. Refer repairs to
qualified service personnel.

CAUTION

!

NATURE OF TROUBLE

POSSIBLE CAUSE

SERVICE

No Hot Water

1. Manual switch turned off

Turn to ON

2. Improper Wiring

** Rewire per Wiring Diagram

3. No Power — blown fuse or circuit breaker tripped

a. Shorted wiring

** Replace or repair

b. Circuit overloaded

** Provide adequate circuit or reduce load

c. Improper wiring

** Rewire per diagram

d. Grounded element or thermostat

** Replace

4. Manual Reset Limit (ECO) open

Refer to "Operation Section"

a. Thermostat(s) defective

** Replace

b.  Thermostat out of calibration

** Lower setting or replace

c. Heat build-up due to loose wires

** Tighten wire connections

d. Defective Limit (ECO)

** Replace

Not enough Hot Water

1. Heater undersized

Reduce rate of hot water use

2. Defective Element(s)

** Check amperage, replace element if low

3. Miswired or defective thermostat

** Check wiring or replace

causing only one element to work

Water too hot or not 

1. Thermostat setting too high or low

Change setting as required

hot enough

2. Thermostat out of calibration

** Replace

Noisy heating element(s)

1. Scale build-up on elements

** Remove and clean

Rattling noise during

1. Heat Trap fitting in operation

None. The rattling noise is normal for

periods of water usage

Heat Traps when in operation and
does not indicate a need for service. 

How to Obtain Service Assistance

1. Should you have any questions about your new water heater, or

if it requires adjustment, repair, or routine maintenance, it is sug-
gested that you first contact your installer, plumbing contractor
or previously agreed upon service agency. In the event that the firm
has moved, or is unavailable, refer to the telephone directory com-
mercial listings or local utility for qualified service assistance.

2. Should your problem not be solved to your complete satisfaction,

you should then contact the Manufacturer’s National Service De-
partment at the following address: 

In the United States:

2600 Gunter Park Drive
Montgomery, Alabama 36109-1413
Phone: 1-800-432-8373. 

In Canada:

Rheem Canada, Ltd./Ltée
128 Barton Street West
Hamilton, Ontario L8N 3P3
Phone: 1-800-432-8373

When contacting the manufacturer, the following information

should be made available:

a. Model and serial numbers of the water heater as shown on the

rating plate attached to the jacket of the heater.

b. Address where water heater is located and can be seen.

c. Name and address of installer and any service agency who per-

formed service on the water heater.

d. Date of original installation and dates any service work was per-

formed.

e. Details of the problem as you can best describe them.

f. List of people, with dates, who have been contacted regarding

your problem.

Model No.

Serial No.

Date of Installation

Installed By:

Содержание Light Duty Commercial Electric Water Heater

Страница 1: ...ructions or any terms within it seek professional advice Any questions regarding the operation maintenance service or warranty of this water heater should be directed to the seller from whom it was pu...

Страница 2: ...can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty Your safety and the safety of ot...

Страница 3: ...CE When this water heater is supplying general purpose hot water requirements for use by individuals a thermostatically controlled mixing valve for reducing point of use water temperature is recommend...

Страница 4: ...suggested typical installation The installation of unions or flexible copper connectors is recommended on the hot and cold water connections so that the water heater may be easily disconnected for ser...

Страница 5: ...ion Box Kit be installed per figure 3 above An opening for either 1 2 or 3 4 electrical fitting is provided for field wiring connections Refer to Figure 3 The voltage requirements and wattage load for...

Страница 6: ...cover any damage or defect caused by installation attachment or use of any type of energy saving or other unapproved devices other than those authorized by the manufacturer into onto or in conjunctio...

Страница 7: ...ater heater remove jacket access panel and insulation exposing thermostats The thermostat protective covers should not be removed Set thermostat dial pointers with a small screwdriver to desired tempe...

Страница 8: ...ter pipe system can be used to minimize the problem Also water hammer arresting devices are usually available from your plumber or local plumbing supply store 2 ANODE ROD INSPECTION The anode rod shou...

Страница 9: ...s normal for periods of water usage Heat Traps when in operation and does not indicate a need for service How to Obtain Service Assistance 1 Should you have any questions about your new water heater o...

Страница 10: ...ER BEF ORE SER VICIN G 140 130 120 110 100 90 T H E R M O D I S C Drain valve Jacket access panel s Heating element gasket Heating element Thermostat bracket Lower thermostat Cavity insulation Lower t...

Страница 11: ...access panel s and insulation 3 Rotate the crossbar up and down until it breaks away from the remainder of the cavity insert See illustration to the left Discard the crossbar It cannot and need not b...

Страница 12: ...ELECTRICAL DISTRIBUTION PANEL G G G BRANCH CIRCUIT TO ELECTRICAL DISTRIBUTION PANEL UPPER THERMOSTAT HIGH TEMP LIMIT ECO 2 UPPER HEATING ELEMENT BLUE L1 JUNCTION BOX 4 L2 1 3 RED 10 GA BLACK LOWER HE...

Отзывы: