Replacement Parts List

Light Duty Commercial

Models

Tall or Short Versions

Instructions for placing a Parts Orders:

Address parts orders to the distributor or store from where the heater was purchased.
All parts orders should include:
1.

Model number and Serial number of heater (from rating plate).

2.

Specify voltage and wattage as marked on rating plate.

3.

Part Description (as noted at right) and number of parts desired.

R

E

SE T

R

E

SE

T

140

130

120

110

100

90

T H

E R

M -

O -

D I S

C

TU

RN

OFF

PO

WE

R

BE

FO

RE

SE

RV

ICIN

G

TU

RN

OF

F

PO

WE

R

BE

FO

RE

SE

RV

ICI

NG

140

130

120

110

100

90

T H

E R

M -

O -

D I

S C

Drain valve

Jacket access

panel(s)

Heating element

gasket

Heating element

Thermostat

bracket

Lower thermostat

Cavity

insulation

Lower thermostat

protective cover

Cavity insulation

Upper thermostat protective cover

(on double element models only)

Upper thermostat

(on double element

models only)

Upper thermostat bracket

(on double element

models only)

Heating element

(on double element

models only)

Heating element

gasket

(on double element

models only)

Dip tube gasket

Dip tube/internal heat trap

Temperature & Pressure

relief valve

Internal heat trap

Internal heat trap

gasket

Some models may have

been supplied with
External heat traps

in lieu of Internal heat traps

Anode

Содержание Light Duty Commercial Electric Water Heater

Страница 1: ...ructions or any terms within it seek professional advice Any questions regarding the operation maintenance service or warranty of this water heater should be directed to the seller from whom it was pu...

Страница 2: ...can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty Your safety and the safety of ot...

Страница 3: ...CE When this water heater is supplying general purpose hot water requirements for use by individuals a thermostatically controlled mixing valve for reducing point of use water temperature is recommend...

Страница 4: ...suggested typical installation The installation of unions or flexible copper connectors is recommended on the hot and cold water connections so that the water heater may be easily disconnected for ser...

Страница 5: ...ion Box Kit be installed per figure 3 above An opening for either 1 2 or 3 4 electrical fitting is provided for field wiring connections Refer to Figure 3 The voltage requirements and wattage load for...

Страница 6: ...cover any damage or defect caused by installation attachment or use of any type of energy saving or other unapproved devices other than those authorized by the manufacturer into onto or in conjunctio...

Страница 7: ...ater heater remove jacket access panel and insulation exposing thermostats The thermostat protective covers should not be removed Set thermostat dial pointers with a small screwdriver to desired tempe...

Страница 8: ...ter pipe system can be used to minimize the problem Also water hammer arresting devices are usually available from your plumber or local plumbing supply store 2 ANODE ROD INSPECTION The anode rod shou...

Страница 9: ...s normal for periods of water usage Heat Traps when in operation and does not indicate a need for service How to Obtain Service Assistance 1 Should you have any questions about your new water heater o...

Страница 10: ...ER BEF ORE SER VICIN G 140 130 120 110 100 90 T H E R M O D I S C Drain valve Jacket access panel s Heating element gasket Heating element Thermostat bracket Lower thermostat Cavity insulation Lower t...

Страница 11: ...access panel s and insulation 3 Rotate the crossbar up and down until it breaks away from the remainder of the cavity insert See illustration to the left Discard the crossbar It cannot and need not b...

Страница 12: ...ELECTRICAL DISTRIBUTION PANEL G G G BRANCH CIRCUIT TO ELECTRICAL DISTRIBUTION PANEL UPPER THERMOSTAT HIGH TEMP LIMIT ECO 2 UPPER HEATING ELEMENT BLUE L1 JUNCTION BOX 4 L2 1 3 RED 10 GA BLACK LOWER HE...

Отзывы: