Cavity Insert Instructions

The following instructions are intended for qualified

service personnel ONLY, and should only be done

when necessary.

In order to replace the thermostat or heating element,
remove the cavity insert crossbar by following the
instructions below:

1.

Turn off the power to the water heater.

2.     Remove the jacket access panel(s) and insulation. 

3.     Rotate the crossbar up and down until it breaks

away from the remainder of the cavity insert.
(See illustration to the left)

Discard the crossbar. It cannot and need not be
replaced.

4.     Replace the thermostat and/or element as

necessary.

5.     Replace the insulation and jacket access panel(s)

before turning on the power to the water heater.

NOTICE: The cavity insert crossbar is necessary for
the manufacturing process only.  The removal of
the crossbar will not interfere with the operation of
the water heater.

Содержание Light Duty Commercial Electric Water Heater

Страница 1: ...ructions or any terms within it seek professional advice Any questions regarding the operation maintenance service or warranty of this water heater should be directed to the seller from whom it was pu...

Страница 2: ...can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty Your safety and the safety of ot...

Страница 3: ...CE When this water heater is supplying general purpose hot water requirements for use by individuals a thermostatically controlled mixing valve for reducing point of use water temperature is recommend...

Страница 4: ...suggested typical installation The installation of unions or flexible copper connectors is recommended on the hot and cold water connections so that the water heater may be easily disconnected for ser...

Страница 5: ...ion Box Kit be installed per figure 3 above An opening for either 1 2 or 3 4 electrical fitting is provided for field wiring connections Refer to Figure 3 The voltage requirements and wattage load for...

Страница 6: ...cover any damage or defect caused by installation attachment or use of any type of energy saving or other unapproved devices other than those authorized by the manufacturer into onto or in conjunctio...

Страница 7: ...ater heater remove jacket access panel and insulation exposing thermostats The thermostat protective covers should not be removed Set thermostat dial pointers with a small screwdriver to desired tempe...

Страница 8: ...ter pipe system can be used to minimize the problem Also water hammer arresting devices are usually available from your plumber or local plumbing supply store 2 ANODE ROD INSPECTION The anode rod shou...

Страница 9: ...s normal for periods of water usage Heat Traps when in operation and does not indicate a need for service How to Obtain Service Assistance 1 Should you have any questions about your new water heater o...

Страница 10: ...ER BEF ORE SER VICIN G 140 130 120 110 100 90 T H E R M O D I S C Drain valve Jacket access panel s Heating element gasket Heating element Thermostat bracket Lower thermostat Cavity insulation Lower t...

Страница 11: ...access panel s and insulation 3 Rotate the crossbar up and down until it breaks away from the remainder of the cavity insert See illustration to the left Discard the crossbar It cannot and need not b...

Страница 12: ...ELECTRICAL DISTRIBUTION PANEL G G G BRANCH CIRCUIT TO ELECTRICAL DISTRIBUTION PANEL UPPER THERMOSTAT HIGH TEMP LIMIT ECO 2 UPPER HEATING ELEMENT BLUE L1 JUNCTION BOX 4 L2 1 3 RED 10 GA BLACK LOWER HE...

Отзывы: