32
FIGURE 31
DOWNFLOW CONDENSATE DRAIN
CONDENSATE DRAIN/NEUTRALIZER
FIGURE 30
UPFLOW CONDENSATE DRAIN
GENERAL INFORMATION
DO NOT RUN DRAIN OUTDOORS.
FREEZING OF CONDENSATE CAN
CAUSE PROPERTY DAMAGE.
IMPORTANT:
Do not connect into a
common drain line with an air con-
ditioner evaporator coil drain located
below the furnace. A blocked or
restricted drain line can result in over-
flow of the coil pan and negate the
furnace blocked drain shutoff control.
FILL TRAP ASSEMBLY WITH WATER
BEFORE OPERATING THE
FURNACE.
This can be done by
removing the drain hose
from the trap and pouring about a
cup of water into the vent trap. Water
will flow into the house drain when the
trap is full.
If local codes require, install a
condensate neutralizer cartridge in the
drain line. Install cartridge in horizontal
position only. Also install an overflow
line if routing to a floor drain. See
Figures 30 and 31.
If no floor drain is available, install a
condensate pump that is resistant to
acidic water. Pumps are available from
your local distributor. If pump used is
not resistant to acidic water, a
condensate neutralizer must be used
ahead of the pump. The condensate
pump must have an auxiliary safety
switch to prevent operation of the
furnace and resulting overflow of
condensate in the event of pump
failure. The safety switch must be wired
through the “R” circuit only (low voltage)
to provide operation in either heating or
cooling modes.
UPFLOW MODELS
The condensate drain trap is located in
the blower compartment on the left-
hand side of the jacket. A short piece of
1
⁄
2
-in. PVC pipe and a
1
⁄
2
-in. tee are
provided. Connect the
1
⁄
2
-in. pipe to the
elbow on the trap and the tee to this
pipe so that the open end is upward.
Run a drain tube from the bottom of the
tee to a floor drain or condensate
pump.
IMPORTANT:
If installing the unit over
a finished ceiling or living area, be
certain to install an auxiliary condensate
drain pan under the entire unit
extending out under the condensate
tee.
IMPORTANT:
There are two options
when choosing a height for the
condensate riser:
CONDENSATE OVERFLOW: With a
5
1
⁄
2
inch riser installed above the tee, a
blocked drain will result in overflow from
the riser.
FURNACE SHUTDOWN: To cause the
furnace to shut down when a blocked
drain is present, install a riser which is a
minimum of 10
13
⁄
16
”. If the furnace is
installed in an attic, crawlspace or other
area where freezing temperatures may
occur, the furnace drain can freeze
while shut off for long periods of time.
Use a solvent cement that is compatible
with PVC material. Cut the drain hoses
to the appropriate length and connect to
the trap with hose clamps. Tighten the
clamps with pliers and check for leaks
after attaching.
DOWNFLOW MODELS
IMPORTANT:
There are two options
when choosing a height for the
condensate riser:
CONDENSATE OVERFLOW: With a
1
3
⁄
4
inch riser installed above the tee,
a blocked drain will result in overflow
from the riser.
FURNACE SHUTDOWN: To cause
the furnace to shut down when a
blocked drain is present, install a riser
which is a minimum of 5
1
⁄
2
”. If the
furnace is installed in an attic,
crawlspace or other area where
freezing temperatures may occur, the
furnace drain can freeze while shut
off for long periods of time.
Use a solvent cement that is
compatible with PVC material.
!
CAUTION
NEUTRALIZER CARTRIDGE
(OPTIONAL)
CONDENSATE TRAP
DRAIN LINE
I408
I408
10
13
/
16
CONDENSATE TRAP
TO FLOOR DRAIN OR CONDENSATE PUMP
OVERFLOW LINE
(REQUIRED ONLY WHEN
OPTIONAL NEUTRALIZER
CARTRIDGE IS USED.)
DRAIN LINE
NEUTRALIZER CARTRIDGE (OPTIONAL)
OVERFLOW LINE
(REQUIRED ONLY WHEN
OPTIONAL NEUTRALIZER
CARTRIDGE IS USED.)
TO FLOOR DRAIN OR CONDENSATE PUMP
NOTE:
SEE UPFLOW MODEL
NOTES FOR PIPE
HEIGHT
NOTE:
SEE DOWNFLOW MODEL
NOTES FOR PIPE HEIGHT
Содержание Gra Series
Страница 58: ...58 FIGURE 57 GRA MODELS WITH UT ELECTRONIC CONTROLS 1028 928 SPARK IGNITION...
Страница 59: ...59 FIGURE 58 GTA MODELS WITH UT ELECTRONIC CONTROLS 1028 928 SPARK IGNITION...
Страница 62: ...62...
Страница 63: ...63...
Страница 64: ...64 CM 0407...