![Rheem *96V series Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/rheem/96v-series/96v-series_installation-instructions-manual_1451371029.webp)
Fie
ld C
on
ve
rsio
ns
SEE CRITICAL HOSE CLAMP LOCATION NOTE IN
THE GENERAL CONVERSION INSTRUCTIONS.
5
CUT
IF REQ’D.
INSTALL
HOSE E
HOSE F
CUT
INSTALL
CUT
INSTALL
ROTATE
UNIT 90°
5a - ROTATE UNIT 90
5b - CUT 1/4" VENT HOSE TO FIT (APPROX. 5-1/2") AND INSTALL AS SHOWN.
5c - CUT HOSE E AT LINE 1- INSTALL
NOTE: MAKE SURE CUT IS STRAIGHT AND SQUARE
5d - CUT HOSE F ON LINE CORRESPONDING TO UNIT WIDTH AND INSTALL
NOTE: 17.5": LINE 1, 21": LINE 2, 24.5": DO NOT CUT
NOTE:
USE SOAPY WATER TO FACILITATE EASY
HOSE AND TUBE ASSEMBLY
1/4” TUBE CUT
TO FIT (APPROX. 4”)
5a
5b
5c
5d
4
4a - REMOVE METAL BRACKET AND THE Ø.403 DRAIN
PLUG- DISCARD.
4b - REMOVE HOSE “A” - DISCARD
4c - INSTALL Ø .559" CONDENSATE DRAIN PLUG AND
CONDENSATE TRAP GASKET AS SHOWN.
4d - INSTALL CONDENSATE TRAP. MAKE SURE THE
CHANNEL AT THE LOCATION SHOWN IN THE “IMPORTANT
SECTION” ENGAGES THE EDGE OF THE JACKET AT THE
LOCATION SPECIFIED.
4e - SECURE USING (3) SCREWS.
NOTE: TO PREVENT DAMAGE TO THE TRAP, THE INSTALLER MAY ELECT TO
INSTALL IT DURING A LATER STEP. (AFTER THE UNIT IS ROTATED)
DISCARD
HOSE A
DISCARD
INSTALL
4a
4b
4c
4d
RECTANGLE PLUG
DISCARD
DRILL (3)
Ø1/8" HOLES
3a - REMOVE RECTANGLE FLUSH MOUNT PLUG
FROM JACKET SIDE-DISCARD
3b - PRE-DRILL (3) Ø 1/8" HOLES AS SHOWN
FOR CONDENSATE TRAP
3a
3b
3
NOTE: REMAINING STEPS SHOWN WITH FURNACE IN HORIZONTAL RIGHT ORIENTATION
ST-A1194-32-01
!! IMPORTANT !!
THIS CHANNEL
MUST ENGAGE
JACKET AT THIS
EDGE TO AVOID
AIR LEAKS TO
THE BURNER
VESTIBULE!
CONDENSATE TRAP
INFORMATION
TRAP
JACKET
INSTALL CONDENSATE TRAP
INSTALL CONDENSATE TRAP
29
Содержание *96V series
Страница 34: ...Field Conversions 34...
Страница 35: ...Field Conversions 35...
Страница 36: ...36 Field Conversions...
Страница 37: ...37 Field Conversions...
Страница 38: ...Field Conversions 38...
Страница 81: ...81 TABLE 14 SUPPLEMENTAL ORIFICE SIZE CHART HIGH ALTITUDE NATURAL GAS AT HIGH ALTITUDES cont High Altitude...
Страница 112: ...112 Diagnostics TABLE 20 continued R96V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS...
Страница 117: ...117 TABLE 20 continued R96V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics...
Страница 123: ...123 FIGURE 62 2 STAGE ECM FURNACE WIRING DIAGRAM Troubleshooting...
Страница 124: ...124 CM 1014...