GENERAL INFORMATION
ITEM
NO.
DESCRIPTION
1
CONDENSATE TRAP
2
DOOR SWITCH
3
JUNCTION BOX
4
TRANSFORMER
5
WATER SENSOR (2)
6
PRESSURE SWITCHES,
HIGH & LOW STAGE
7
EXHAUST TRANSITION
8
COUPLING (ELBOW TO TRANSITION)
9
EXHAUST
10
SHIPPING PLUG
11
FLAME SENSOR
12
OVER TEMPERATURE SWITCH
13
TOP PLATE
14
BURNER
15
IGNITER
16
COMBUSTION AIR INLET
17
GAS VALVE
18
INDUCED DRAFT BLOWER (IDB)
19
POWER FACTOR CORRECTION CHOKE
(PFC) (NOT USED ON THE 42KBTU,
56KBTU AND 70KBTU)
20
CONTROL MOUNTING PLATE
21
BLOWER
22
LOW VOLTAGE TERMINAL
23
COUPLING (IDB TO ELBOW)
24
MAIN LIMIT
25
FURNACE CONTROL
ST-A1205-01
FIGURE 1
FURNACE COMPONENTS
NOTE:
A heat loss calculation should be performed to
properly determine the required furnace BTU size for the
structure. Also, the duct must be properly designed and in-
stalled for proper airflow. Existing ductwork must be in-
spected for proper size and to make sure that it is properly
sealed. Proper airflow is necessary for both user comfort
and equipment performance.
Before opening the furnace carton, verify that the data
tags on the carton specify the furnace model number
that was ordered from the distributor and are correct
for the installation. If not, return the unit without open-
ing the carton. If the model number is correct, open
the carton and verify that the furnace rating label
specifies the same furnace model number that is
specified on the carton label. If the model numbers do
not match, return the furnace to the distributor.
IMPORTANT:
Proper application, installation and mainte-
nance of this furnace and system is a must if consumers
are to receive the full benefits for which they have paid.
The (-)96V and (-)(-)96MDV series furnaces are design-
certified by CSA for use with natural and propane gases as
follows:
1. As non-direct vent central forced air furnaces taking
combustion air from the installation area or using air
ducted from the outside.
2. As direct vent central forced air furnaces with all com-
bustion air supplied directly to the furnace burners
through a special air intake system outlined in these
instructions.Install this furnace in accordance with the
American National Standard Z223.1 – latest edition
entitled “National Fuel Gas Code” (NFPA54) or, for
Canada, CSA B149.1; Canadian Natural Gas and
Propane Installation Code and requirements or codes
of the local utilities or other authorities having jurisdic-
tion. This is available from the following:
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
CSA-INTERNATIONAL
5060 Spectrum Way
Mississauga, Ontario
Canada L4W5N6
Online: www.csa.ca
3
21
23
20
22
4
3
13
16
15
17
5
18
19
2
1
5
6
9
8
7
11
10
12
14
24
25
Содержание 96MDV Series
Страница 34: ...Field Conversions 34...
Страница 35: ...Field Conversions 35...
Страница 36: ...36 Field Conversions...
Страница 37: ...37 Field Conversions...
Страница 38: ...Field Conversions 38...
Страница 81: ...81 TABLE 14 SUPPLEMENTAL ORIFICE SIZE CHART HIGH ALTITUDE NATURAL GAS AT HIGH ALTITUDES cont High Altitude...
Страница 115: ...115 TABLE 20 continued R96V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics...
Страница 120: ...120 Diagnostics TABLE 20 continued R96V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS...
Страница 126: ...126 FIGURE 65 2 STAGE ECM FURNACE WIRING DIAGRAM Troubleshooting...
Страница 127: ...127...
Страница 128: ...128 CM 1015...