background image

INSTALLATION – SOLAR COLLECTORS 

11 

INCLINATION OF SOLAR COLLECTORS 

To help maximise system performance, solar collectors should be installed with 
an optimum inclination. This is equal to 90% to 100% of the local latitude angle 
when collectors are oriented within 60° of true north or true south, and between 
10°  and  20°  when  the  collectors  are  oriented  between  60°  and  90°  from  the 
optimum orientation. 
 
Generally,  improved  summer  performance  is  obtained  from  an  angle  of 
inclination  less  than  the  optimum  angle  and  improved  winter  performance  is 
obtained by an angle of inclination greater than the optimum angle. If the angle 
of  inclination  varies  by  20°  from  the  optimum  angle,  the  solar  collectors  will 
receive  about  10%  less  total  annual  solar  radiation.  The 

latitude  of  some 

Australian cities

 are listed on page 12. 

 
However,  the  optimum  inclination  of  solar  collectors  is  not  always  practical  or 
achievable.  Solar  collectors may  be  installed  at  the  roof angle for  simplicity  of 
installation  and  appearance,  but  must  never  be  flat  for  a  pumped  solar  open 
circuit water heater installation. Although the solar collectors can be installed with 
an inclination of less than 10°, this is not advised. The risks include: 

 

the collector glass not 'self-cleaning', leading to dirty collector glass reducing 
solar performance, and 

 

condensation on the underside of the glass taking longer to clear, and 

 

condensation  droplets  falling  onto  the  absorber  plate  potentially  causing 
discolouration. 

The collector kit is suitable for installations with an inclination of up to 45°. Where 
the  solar  collectors  are  installed  at  inclinations  greater  than  45°,  a  With  Pitch 
frame is necessary. Refer to your local Solar Distributor for details. 
 
A Variable Pitch frame can be installed to increase the angle of inclination of the 
collectors used in a pumped solar water heater installation. This type of frame 
should be used if the roof pitch either varies by more than 20° from the optimum 
angle or is less than 10°. 
 
The use of a Variable Pitch frame should be discussed with the system owner. If 
this  option  is  neither  possible  nor  acceptable  to  the  system  owner,  it  may  be 
possible for an additional solar collector to be installed to help make up for the 
reduction in solar performance compared to the optimum inclination. This option 
should be discussed with the system owner. 
 
If these options are neither possible nor acceptable to the system owner, then 
the  system  owner  needs  to  be  made  aware  of,  understand  and  accept  that 
increased boosting may be required to meet their hot water requirements. 
 

 

Содержание 12104793

Страница 1: ...ith Copper Waterways Conetite Connections for use in Open Circuit Systems using uncoated DR Brass Conetite fittings LCS TBT200 SOLAR COLLECTORS WARNING Plumber Be Aware Use copper pipe ONLY Plastic pi...

Страница 2: ...ustralia be weatherproof and UV resistant if exposed extend through any penetrations in the eaves ceiling and roof cover valves and fittings in the solar pipe work be fitted up to and cover the connec...

Страница 3: ...ed Views Solar Collectors 36 Warranty Note 39 Notice to Victorian Customers from the Victorian Plumbing Industry Commission This water heater must be installed by a licensed person as required by the...

Страница 4: ...ctors Collector Kit Conetite Fittings 2 Collectors uncoated brass conetites 12104794 LCS TBT200 solar collectors Collector Kit Conetite Fittings Additional Collector uncoated brass conetites 12104795...

Страница 5: ...s 2 2 341391 Collector bung end plug assembly conetite brass consisting of 1 x 344236 collector bung uncoated 1 x 337116 gland nut 2 2 344269 Sensor connector fitting conetite brass 15BSP temp assbly...

Страница 6: ...of correct height safety equipment harnesses etc All other relevant safety factors specific to the installation and maintenance work to be compliant with suitable Occupational Health and Safety Regula...

Страница 7: ...de advice to the system owner about their needs and building back up redundancy into the hot water supply system OPEN CIRCUIT SYSTEM INSTALLATION An open circuit system has a collector circuit which i...

Страница 8: ...he solar storage tank in relation to the solar collectors There are limitations on both the maximum length of the solar hot and solar cold pipes and the maximum height between the solar storage tank a...

Страница 9: ...STRENGTH The installer must ensure the structural integrity of the building is not compromised by the solar water heater installation and the roof structure is suitable to carry the full weight of th...

Страница 10: ...ake up for the reduction in solar performance compared to the optimum orientation This option should be discussed with the system owner If this option is neither possible nor acceptable to the system...

Страница 11: ...vised The risks include the collector glass not self cleaning leading to dirty collector glass reducing solar performance and condensation on the underside of the glass taking longer to clear and cond...

Страница 12: ...frame or up to and within Wind Region C Variable Pitch frame as defined in the Building Code of Australia Australian Standard AS 4055 and the Australian New Zealand Standard AS NZS 1170 2 or equivalen...

Страница 13: ...al 90 bend reduce the maximum total pipe length by 0 5 m For each additional metre of pipe length reduce the number of 90 bends by two Note One 90 elbow is equal to two 90 bends NR not recommended NA...

Страница 14: ...or a Class 1a or Class 10 building as applicable under the Plumbing Code of Australia be weatherproof and UV resistant if exposed extend through any penetrations in the eaves ceiling and roof cover va...

Страница 15: ...n circuit system Plastic pipe MUST NOT be used as it will not withstand the temperature and pressure of the water generated by the solar collectors under stagnation conditions Extremely high water tem...

Страница 16: ...ded total pipe length for the system and the water supply pressure The maximum recommended total pipe length of the solar circuit should not be exceeded and a minimum water supply pressure of 200 kPa...

Страница 17: ...rity requirements or on other occasions where the solar collectors and solar hot and solar cold pipes are installed prior to the solar storage tank such as on a building site Collector Circuit Warning...

Страница 18: ...emove only sufficient packaging material to enable the installation of the solar collectors Upon completion of the installation of the solar collectors with conetite fittings such as on a building sit...

Страница 19: ...e than two solar collectors 17 are installed locate the collector rail 1 from the Additional Collector kit adjacent to the first collector rail 1 and join together using the drive cleat 8 supplied in...

Страница 20: ...solar collector or 30 40 mm for two solar collectors or 45 60 mm for three solar collectors This is to provide a downward angle along the top end of the collectors to assist in rainwater runoff in ord...

Страница 21: ...ted in the collector rail 1 and prior to positioning the next solar collector firmly clamp two clamps per collector to the collector rail using the clamps hex screws washers and nuts provided Repeat t...

Страница 22: ...Clamp the solar collectors 17 two clamps per collector to the collector rail 1 using the clamps 13 hex screws washers and nuts provided Refer to Clamping Collector to Collector Rail on page 29 9 Fixin...

Страница 23: ...n open circuit system Refer to Pipe Lengths on page 13 The solar hot and solar cold pipes must have a continuous fall from the solar collectors to the solar storage tank Horizontal runs of pipe work a...

Страница 24: ...tion Instructions supplied with the solar storage tank for the connection detail Tank with side solar connections and side mounted solar control unit Connect the hot sensor lead to the hot sensor cabl...

Страница 25: ...completion of the installation refer to the Owners Guide and Installation instructions supplied with the solar storage tank for the commissioning procedure of the solar water heater INSTALLATION CHEC...

Страница 26: ...commended slots Rafter spacing One collector 1 x one collector rail Two collectors 1 x two collector rail 300 mm 12 1 4 or 2 3 1 6 or 2 5 400 mm 16 1 3 or 2 4 1 5 or 2 6 450 mm 18 1 4 2 5 500 mm 20 1...

Страница 27: ...Detail A Top collector rail slide the long straight end of the collector strap through the appropriate slot from the top side of the collector rail refer to Detail B Pull the collector strap through u...

Страница 28: ...Hand tighten only so the solar collectors can be shifted and centred 2 Place the collector unions 3 into the collector connections on the second solar collector and screw in the unions until they sea...

Страница 29: ...G ASSEMBLY CONETITE FITTING CLAMPING COLLECTOR TO COLLECTOR RAIL Refer to installation diagrams on pages 36 to 38 for position and Detail E on page 30 and Detail F on page 30 1 Centre the solar collec...

Страница 30: ...30 DETAIL E CLAMPING COLLECTOR TO COLLECTOR RAIL BOTTOM DETAIL F CLAMPING COLLECTOR TO COLLECTOR RAIL TOP PART NUMBERS ARE SUPPLIED IN COLLECT AR OPEN CIRCUIT PUMPED SYSTEM DESIGN L SHEET COLLECTORS...

Страница 31: ...n 2 Place the compression nut 11 and olive 12 over the end of the solar cold pipe Position the cold pipe into the connector 10 assembly seat the olive 12 and tighten the compression nut 11 3 Repeat th...

Страница 32: ...T CONNECTION TO SOLAR COLLECTOR DETAIL J SENSOR CONNECTOR ORIENTATION TILED ROOF ITEMS WITH PART NUMBE SOLAR OPEN CIR DETAIL SHEET CO Tiled roof 30 Down roof Hot sensor connector assembly range is fro...

Страница 33: ...Circuit A Hot Outlet B C D E Gas Pipe Work to 160 Solar Storage Tank Hot Outlet 20L Hot Outlet 24L 26L Hot Outlet 27L Solar Hot Flow Solar Cold Return Cold Inlet Gas 20L Gas 24L 26L integrated gas boo...

Страница 34: ...to Solar Storage Tank Capacity litres Hot Outlet Solar Hot Flow Solar Cold Return Cold Inlet 270 tank 270 1190 685 635 73 320 325 tanks 325 1430 754 635 73 410 tank 410 1600 820 643 81 Note the rough...

Страница 35: ...PIPE WORK ROUGHING IN DIMENSIONS 35 Solar Pipe Work Roughing In Dimensions Pipe Work to Solar Collectors E F 1 Collector 1200 1875 2 Collectors 2260 1875 3 Collectors 3320 1875 IMENSIONS...

Страница 36: ...hex screw washer nut 14 Cable tie 15 Label solar hot pipe 16 Label solar cold pipe Supplied separately 17 Solar collector Solar Cold Pipe to collectors Solar Hot Pipe from collectors apply to solar h...

Страница 37: ...olar Hot Pipe from collectors apply to solar hot pipe at storage tank level apply to solar cold pipe at storage tank level SUPPLIED IN COLLECTOR KIT 2 COLLECTORS 2280 2000 5 3 3 17 SOLAR DIRECT TWO CO...

Страница 38: ...1 ADDITIONA 1 Collector rai 2 Collector str 3 Collector un 8 Driver cleat 13 Clamp hex SUPPLIED SE 17 Solar Collec SOLAR DIRECT COLLECTOR INSTALLATION ADDITIONAL COLLECTOR EXPLODED VIEW WITH UNCOATED...

Страница 39: ...of c Installation not in accordance with the Owner s Guide and Installation Instructions or with relevant statutory and local requirements in the State or Territory in which the water heater is instal...

Страница 40: ...or more patents or registered designs in the name of Rheem Australia Pty Ltd or Solahart Industries Pty Ltd TRADEMARKS Registered trademark of Rheem Australia Pty Ltd or Solahart Industries Pty Ltd T...

Отзывы: