CONNECTION DETAILS
28
COUPLING COLLECTOR TO COLLECTOR
– CONETITE FITTING
Refer to
installation diagrams on pages
page 28.
1.
Fit a collector union (3) to each collector connection of the first solar
collector (17) to receive the second solar collector and screw in the unions
until they seat firmly against the collector connection. Hand tighten only so
the solar collectors can be shifted and centred.
2.
Place the collector unions (3) into the collector connections on the second
solar collector and screw in the unions until they seat firmly against the
collector connection. Hand tighten only so the solar collectors can be shifted
and centred.
3.
Repeat steps 1 and 2 for a third solar collector (if installed).
4.
After the solar collectors are centred on the collector rail(s), tighten each
collector union (3) with a spanner applying medium pressure.
DETAIL C – COLLECTOR UNION ASSEMBLY – CONETITE FITTING
(ITEMS WITH PART NUMBERS, ARE SUPPLIED IN COLLECTOR KIT)
SOLAR OPEN CIRCUIT PUMPED SYSTEM DESIGN
DETAIL SHEET - COLLECTORS CONETITE FITTINGS