background image

 

DTR_314-05-01-001_EN_a

 

1.

 

Specification 

RM-470 remote display  

Dimensions: 

1

 

679mm x 242mm x 74mm / 26.7in x 9.5in x 2.9in 

Digit height: 

120mm / 4.7in 

Accepted input voltage range (long-term): 

100 ÷ 240 VAC 

Accepted input voltage range (short-term): 

85 ÷ 264 VAC 

Accepted input voltage range:  

47 ÷ 63 Hz 

Operating temperature (ambient):  

-25°C ÷ 45°C / -13°F ÷ 113°F 

Operating temperature (device surface):  

-25°C ÷ 70°C / -13°F ÷ 158°F 

Average power consumption: 

7W 

Ingress protection rating

2

IP 65 / NEMA 4 

Device weight: 

5kg / 11lbs 

2.

 

Transport and storage  

The device is sensitive to mechanical damage. It should be ensured that it is properly secured for transport so as 
to  avoid  any  damage  caused  during  transportation.  It  is  forbidden  to  transport  the  device  components 
separately in a collective package – each item must be packed individually and cannot hit one another during 
transportation.  
 
The  device should be  stored in the temperature of  -20°C to +60°C, at the humidity below 99% RH due to the 
protective packaging.  

3.

 

Device construction 

RM-470  is  manufactured  in  a  powder-coated  steel  housing.  The  properly  installed  device  is  characterised  by 
tightness class IP65. 

3.1

 

RM-470 construction  

The figure shows the RM-470 remote display construction

3

 

 

 

det. A

 – annuciators;

 det. B

 – screen; 

det. C

 – sliding drawer with controller board; 

det. D

 – drawer fixing screw; 

det. E

 – device front; 

det. 

F

 – mounting bracket; 

det. G

 – fixing screw; 

det. H

 – brightness sensor; 

Fig. 1 

                                                           

1

 Dimensions without accessories, 

2

 Ingress protection rating according to EN 60529 standard, 

3

 Explanatory figure  

 

 

Содержание 314-05-01

Страница 1: ...OPERATION AND MAINTENANCE MANUAL RM 470 Product code 314 05 01 Explanatory figure OPERATION AND MAINTENANCE MANUAL RM 470 Product code 314 05 01...

Страница 2: ...rates 6 4 3 3 RGB WagSet 2 software 6 4 3 4 Web panel 7 5 Display controller board 7 5 1 Connectors and buttons on the controller board 7 5 2 List of connectors of the display controller board 8 5 2 1...

Страница 3: ...during transportation It is forbidden to transport the device components separately in a collective package each item must be packed individually and cannot hit one another during transportation The...

Страница 4: ...e device 4 2 Autolearn function The Autolearn mode is enabled by default position 0 is set in the proto submenu To disable it the communication protocol should be selected manually using the embedded...

Страница 5: ...oswitch used to operate the menu is located inside the display and is accessible after unscrewing two screws M4x10 Fig 3 det A and after pulling out the drawer as indicated by the black arrow The micr...

Страница 6: ...t 2 software 2101 and communication port for the weighing terminal 2102 To restore the default settings you should during the normal operation of the device press the microbutton and hold it down unti...

Страница 7: ...er board The controller board is responsible for processing and displaying the weighing result incoming from the weighing indicator 5 1 Connectors and buttons on the controller board det A LED module...

Страница 8: ...ARD 4 Interface Function Connector markings Notes RS 232 RA The RXD line of the RS 232 interface should be connected with the weighing indicator TXD output RK GND line of the RS 232 interface 0 20mA C...

Страница 9: ...2 software via RS 485 RS 422 connector 5 2 3 0 20mA digital current loop For configuration purposes the user connects the remote display to the computer with installed RGB WagSet 2 software via digita...

Страница 10: ...ls Fig 8 Fig 9 6 3 Mounting brackets Fig 10 Pole mounting brackets are available in the following sizes 2 pole outer diameter 60 3 mm 3 pole outer diameter 84 0 88 9 mm 4 pole outer diameter 111 1 115...

Страница 11: ...bol _ in the bottom right corner It means that the user has 7 seconds to send the configuration to the remote display If no configuration is sent to the device it will launch the Autolearn process 9 D...

Отзывы: