background image

 

DTR_314-05-01-001_EN_a

 

4.3.4

 

Web-panel  

The embedded Web panel allows: 
- selecting the communication protocol of the weighing indicator, 
- changing the network settings, 
- checking the version of and updating the display software, 
The  detailed  information  concerning  the  Web-panel  operation  and  its  capabilities  can  be  found  in  the  device 
operation manual. 

5.

 

Display controller board 

The  controller  board  is  responsible  for  processing  and  displaying  the  weighing  result  incoming  from  the 
weighing indicator. 

5.1

 

Connectors and buttons on the controller board  
 

 

 

det. A

 – LED module connector; 

det. B

 – brightness sensor connector; 

det. C

 – RS-485/RS-422 connector; 

det. D

 – 0/20mA digital current 

loop; 

det. E

 – RS-232 connector; 

det. F

 – RS isolated interface connector; 

det. G

 – microswitch (B1, B2, B3); 

det. H

 – mains power supply 

connector; 

det. I

 – radioline connector; 

det. J

 – controller power supply [5V]; 

det. K

 – Ethernet connector; 

det. L

 – status LEDs (D1 wired 

data transmission). 

Fig. 4 

 

 

 

Содержание 314-05-01

Страница 1: ...OPERATION AND MAINTENANCE MANUAL RM 470 Product code 314 05 01 Explanatory figure OPERATION AND MAINTENANCE MANUAL RM 470 Product code 314 05 01...

Страница 2: ...rates 6 4 3 3 RGB WagSet 2 software 6 4 3 4 Web panel 7 5 Display controller board 7 5 1 Connectors and buttons on the controller board 7 5 2 List of connectors of the display controller board 8 5 2 1...

Страница 3: ...during transportation It is forbidden to transport the device components separately in a collective package each item must be packed individually and cannot hit one another during transportation The...

Страница 4: ...e device 4 2 Autolearn function The Autolearn mode is enabled by default position 0 is set in the proto submenu To disable it the communication protocol should be selected manually using the embedded...

Страница 5: ...oswitch used to operate the menu is located inside the display and is accessible after unscrewing two screws M4x10 Fig 3 det A and after pulling out the drawer as indicated by the black arrow The micr...

Страница 6: ...t 2 software 2101 and communication port for the weighing terminal 2102 To restore the default settings you should during the normal operation of the device press the microbutton and hold it down unti...

Страница 7: ...er board The controller board is responsible for processing and displaying the weighing result incoming from the weighing indicator 5 1 Connectors and buttons on the controller board det A LED module...

Страница 8: ...ARD 4 Interface Function Connector markings Notes RS 232 RA The RXD line of the RS 232 interface should be connected with the weighing indicator TXD output RK GND line of the RS 232 interface 0 20mA C...

Страница 9: ...2 software via RS 485 RS 422 connector 5 2 3 0 20mA digital current loop For configuration purposes the user connects the remote display to the computer with installed RGB WagSet 2 software via digita...

Страница 10: ...ls Fig 8 Fig 9 6 3 Mounting brackets Fig 10 Pole mounting brackets are available in the following sizes 2 pole outer diameter 60 3 mm 3 pole outer diameter 84 0 88 9 mm 4 pole outer diameter 111 1 115...

Страница 11: ...bol _ in the bottom right corner It means that the user has 7 seconds to send the configuration to the remote display If no configuration is sent to the device it will launch the Autolearn process 9 D...

Отзывы: