10
DTR_102-02-07-001_EN_f
5.15
Hardware restoring of the clock factory settings
To
do the hardware restoring of the clock factory settings,
you should:
1)
Disconnect the device from the power supply.
2)
Make sure that a cable is not connected to the
GPS
connector (disconnect if it happens).
3)
Connect the
GPS
pin to the
GND
pin in the connector.
4)
Switch on the power.
5)
Wait (about 3 seconds) until the clock signals the resetting of the settings by blinking of the middle
segments of the digits.
6)
Disconnect the
GPS
pin and
GND
pin
NOTICE!
The function mentioned above causes the resetting of all the settings of the device, but it doesn't reset the
remote control codes. When the device is equipped with a LAN module, the network settings will be reset as
well.
6
Daylight saving time
In accordance with EU Directive 2000/84/EC:
- the standard time is changed to the daylight saving time on the last Sunday in March (adding one hour),
- the daylight saving time is changed to the standard time on the last Sunday in October (taking away one hour).
Considering the above, in the countries following EU Directive 2000/84/EC, when the option of taking into
account the daylight saving time is activated in the clock:
a)
On the last Sunday in March
there is no time interval between 01:00UTC + TimeZone and
01:59UTC + TimeZone. If you try to set the clock to the time within this interval, one hour earlier value is
adopted, and it is assumed that the time has not yet been changed to the daylight saving time. As a result,
within the nearest 60 minutes, the clock will take into account the change to the daylight saving time and will
add one hour automatically.
b)
On the last Sunday in October,
the time interval between 01:00UTC + TimeZone and 01:59UTC + TimeZone
appears twice. If you set the clock to the time within this interval, the clock will be set to the time indicated by
the user, and it is assumed that the time has already been changed to the standard time.
7
Initial start-up
Step 1: Connect the clock to the power supply,
Step 2: Within 60 seconds proceed with the IR remote control pairing combinations,
Step 3: When properly paired, the clock will display the inscription "SAVE" and, next, will proceed to displaying
the time.
8
Disposal and recycling
8.1
Packaging material recycling
The packaging elements must be segregated and, then, recycled in accordance with the local executive
regulations on waste disposal.
8.2
Device disposal
The device must not be disposed of as urban waste!
In accordance with the directive 2002/96/EC (WEEE), if the repair of the device is not economically justified, the
user must take the damaged or destroyed equipment to a special waste disposal centre.