This screen will be displayed,
showing the Date and Time that
the alarm occurred.
8.5.1.1
Press the Info (
) Button
to see the detail of the
alarm.
See section 13.12 for troubleshooting information.
8.5.2
High Humidity Alarm –
Occurs when the Humidity level (
HUMIDITY
) rises above the alarm
threshold for more than one (1) minute. The air dryer will go into
SHUTDOWN
mode to prevent saturated air from being delivered to the
supply line. (Default setting is 10%)
This screen will be displayed,
showing the Date and Time that
the alarm occurred.
8.5.2.1
Press the Info (
) Button
to see the detail of the
alarm.
See section 13.10 for troubleshooting information.
8.5.3
Low Outlet Pressure Alarm –
Occurs when the Outlet Pressure (
OUTLET
) drops below the alarm
threshold for more than one (1) minute. (Default setting is 0.30 PSI/2.0KPa)