I/O Terminal on router
DB9 Serial port (RS485 or
RS232)
Port 3 (GND)
Pin 5
Port 4 (RX)
Pin 3
Port 5 (TX)
Pin 2
Notes: If not through, can switch Port4 and port5.
2.6 Grounding
To ensure a safe, stable and reliable RF-R586 series operation, Router cabinet
should be grounded properly.
2.7 Power Supply
RF-R586 series can be applied to complicated external environment and usually the
power range is very large. So in order to fit the complicated application environment
and improve the stability of the system, RF-R586 series is designed with advanced
power management technology. The DC power supply electronic to the device via
the pluggable terminal PIN 2(GND) and PIN 1(Vin). Please refer to the above table
for the detail definition of the terminal.
Normally, RF-R586 series input powers supply is +5
~
+40V (if your RF-R586
support 50V, the option is +5~+50V). In most cases, the standard configuration is
12V/1A.
2.8 LED and Check Network Status
Please connect the antenna after you successfully connect to the cable. And then
insert the valid SIM/UIM card and provide the power to the RF-R586 series via the
cable. After provide the power to RF-R586, if the SYS LED starts to blink in a few
seconds, that means the system start-up is normal; if the CELL LED works, that
means the network is online; if the VPN light works, that means VPN tunnel has
been set up. Please refer to the below table for the situation of the indication lights.