RF-R586 Series Industrial Grade Cellular Router
P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466
52
Operation Mode
Active: disable or enable the link redundancy
Back to Higher Primary When Possible:
If you tick this option, once the RF-R586 Router work on backup link, whether it fails or
not, it will return to main link if main link turns to be okay.
If not tick this option, the RF-R586 Router will not return to main link until the current link
fails.
Link Priority Settings
WAN1: Cellular Wireless
WAN2: WiFi DHCP Wireless
WAN3: Wired XXX (XXX=DHCP, STATIC, PPPOE)
OFF: Check OFF Blank to disable or uncheck to enable the link redundancy
Priority: High Priority, Middle Priority, Low Priority.
Link Check Settings
Check Count: for example, set it as 3. Router check link live 3 times.
Check Interval Time(min): for example, set is as 2. Router check link live every 2
minutes.
Used The Same Method:
If set it as YES, WAN1/WAN2/WAN3 use same check IP or domain name from ALL
WAN Check Method.