![RFnivo rf3000 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/rfnivo/rf3000/rf3000_technical-information-and-instructions_1450404013.webp)
Level limit switch
Series RF 3000
Technical Information / Instruction manual
page
Approvals
General Purpose *
(Ordinary Locations)
CE
FM / FMc
TR-CU
EN 61010-1
Hazardous
Locations *
ATEX
Dust explosion
Gas explosion
Protection by enclosure
Flameproof
Flameproof / increased safety
II 1/2D Ex
ia/tb
IIIC T! Da/Db
II 2G Ex d ia IIC T! Gb
II 2G Ex de ia IIC T! Gb
IEC-Ex
Dust explosion
Gas explosion
Protection by enclosure
Flameproof
Flameproof / increased safety
Ex
ia/tb
IIIC T! Da/Db
Ex d ia IIC T! Gb
Ex de ia IIC T! Gb
FM / FMc
Dust explosion
Gas explosion
Protection by enclosure
Flameproof
DIP-IS Cl. II, III Div.1 Gr. E,F,G
XP-IS Cl. I Div.1 Gr. B,C,D
Cl. I Zone 1 Gr. IIB+H2
TR-CU
Dust explosion
Gas explosion
Protection by enclosure
Flameproof
Flameproof / increased safety
Ex ia/tb IIIC T! Da/Db X
Ex d ia IIC T! Gb X
Ex de ia IIC T! Gb X
Detailed allocation of types and electronic modules to approvals: see selection list.
EMC
EN 61326 -A1
Hygiene *
EHEDG (Type ED)
Food grade material
According to directive 1935/2004/EC
Pressure Equipment
Directive
(2014/68/EU)
The units are not subject to this directive, because they are classified as „pressure-keeping equipment“ and
do not have a pressurized housing (see Art.1, clause 2.1.4).
The units are designed and manufactured in accordance to the Pressure Equipment Directive.
The unit is NOT intended for use as a “equipment part with safety function (Art.1, clause 2.1.3).
If the units should be used as „equipment part with safety function, please contact the manufacturer.
* depending on selected version in the selection list.
Approvals / Options
Options
Various options are available, see pricelist for more details:
Remote version
• Probe and electronic housing separated (cable length up to 20m (65ft))
Electronics
• Preselected sensitivity (factory setting of switching sensitivity )
Probes
• Coating rod version
• Coating rope version (rope)
• Extension kits (rigid or flexible rod extension, rope extension)
Mounting
• Sliding sleeve (flexible height adjustment of the probe)
• EHEDG approval (Type ED)
• Mounting sets: Screws, washers, sealings for fixing the unit on a flange.
Housing
• Housing material plastics PA6
• Weather protection cover (PE, weathering and temperature stable)
• Cable entry (metric or NPT with different size)
• Signal lamp (indiation of signal output state from outside)
• Plugs (valve connector, M12 plug, Harting)
RFnivo
®
1
2
3
4
5
6
7
8
9
10
11
12
RF 3000 d
gi241014
13