The RFL 3000 4K24 Switch fits nicely in this environment, and offers future
backbone expansion. The 24 switched copper ports are provfided by a RFL 3000 4K24.
Should the number of servers expand, more than one server can be accessed at full speed
from any switched 4K24 port by any of the users simultaneously.
Router
10
10
2 4X 6 8 10 12 14 16 18 20 22 24
1X 1 3X 5 7 9 11 13 15 17 19 21 23
Magnum 4016C Switch
100M
Col/FDX
Link/Act
Power
100M
Col/FDX
Link/Act
10
Fig 2.4c: RFL 3000 4K24 provides a 10/100Mb Switch with non-blocking
performance for small a office
3.0
Installation
Before installing the equipment, it is necessary to take the following precautions:
1.)
If the equipment is mounted in an enclosed or multiple rack assembly, the
environmental temperature around the equipment must be less than or equal to 50
0
C.
2.)
If the equipment is mounted in an enclosed or multiple rack assembly, adequate air
flow must be maintained for proper and safe operation.
3.)
If the equipment is mounted in an enclosed or multiple rack system placement of
the equipment must not overload or load unevenly the rack system.
4.)
If the equipment is mounted in an enclosed or multiple rack assembly, verify the
equipment’s power requirements to prevent overloading of the building/s electrical
circuits.
5.)
If the equipment is mounted in an enclosed or multiple rack assembly verify that
the equipment has a reliable and uncompromised earthing path.
6.)
If the intra-building wiring (cabling) is involved with this product(NEBS), then it
is recommended to have shielded cable and the shield is grounded at both ends.
Installation:
This section describes installation of the RFL 3000 4K-Series Switches, as
well as connection of the various Ethernet media types.
3.1
Locating RFL 3000 4K24 Switches