Selecting a Tone for the Alarm 

Tone starts and continues sounding when you press 

and hold the Sound select button. Release the button 

and then press the button again to listen to the next 

Tone. Repeat u

n

til you decide which Tone to use. 

Tone 

Pi-Pi- Pi-Pi-

PuPi- PuPi-

PuPi-PuPi-PuPi-

PuPiPiPuPiPi

Pi--- Pi Pi

Pi Pi Pi Pi

PiPi- PiPi-

PiPiPi PiPiPi

To Turn Off the ST710 

1. Press the Hold button.

2. Unplug the sensor.

3. The unit will turn off in 30 seconds.

� Dispose of Properly

-

If you no longer use the device or its accessories, 

dispose of according to the local regulations in force. 

ST710 Instruction Manual (0510-0519-

B

Mounting Attachments 

The ST710 can be fitted with the following attachments: 

Strap 

The strap is attached to the ST710 through a strap hole and 

can be attached to a bed, chair or handrail. 

Mounting Clip 

The ST710 unit can be attached to the wall or chair through 

a stainless steel wheelchair clip or wall mounting bracket. 

Strap hole 

Strap 

Clip mounting unit 

�� 

Chair clip 

Wall mount clip 

Alarm Indicators 

LED status 

Indicates unit is in 

Solid GREEN 

30 second hold 

Flashing RED 

Alarm 

twice per second 

Blinking RED 

Low Battery state. 

every 

seconds 

When using batteries, the ST710 

will alarm every 15 second and the 

red LED will blink every 

5

seconds. Replace the battery as 

soon as possible when the Low 

Battery is indicated. 

Flashing Green 

Unit is monitoring a patient. 

every 3 seconds 

Page  9  of 11 

Содержание Sensatec ST710

Страница 1: ...ST710 Instruction Manual PN 0510 0519 B Release Date 11 17 17 3125 North 126 th Street Brookfield WI 53005 USA phone 800 669 9946 web www rft com ...

Страница 2: ...3 WARNINGS 4 CAUTIONS 4 ST710 CONTROL UNIT 6 FRONTSIDE 6 INSIDE BATTERY Box 6 USING THEST710 SYSTEM 7 BED MODE 7 CHAIR MODE 7 FLOOR MODE 8 SELECTING A TONE FOR THE ALARM 9 To TURN OFF THEST710 9 DISPOSE OF PROPERLY 9 MOUNTING ATTACHMENTS 9 ALARM INDICATORS 9 TESTING THE SYSTEM AND TROUBLESHOOTING 10 TESTING THESYSTEM 10 TROUBLESHOOTING 10 SPECIFICATIONS 11 Page 2 of 11 ST710 Instruction Manual 051...

Страница 3: ...terference to be used in hospitals clinics and other institutions which are environmentally qualified The use ofthis equipment in an inappropriate environment may cause electronic interference This equipment can be used in residential areas only ST710 Instruction Manual 0510 0519 B Before Using the ST710 Be sure to read the Instruction Manual thoroughly before using to get a full understanding oft...

Страница 4: ...teries Explosion and liquid leak ofbattery may lead to fire and injury Inspect the plug and the outlet regularly Remove the dust and dirt between the plug and the outlet regularly Failure to do so may result in short circuit and fire CDcautions SENSATEC fall monitors are designed to be used with the SENSATEC pressure sensor pads and other accessories to construct a fall monitoring system It is int...

Страница 5: ...g the device for an extended period of time Ifthere is corrosion on the battery terminals clean and wipe offthe battery case and replace with new batteries Ifthe liquid leak comes in contact with body rinse well with water Sensor pad cautions To keep the sensor pads in good condition Do not immerse the sensor pad into liquid ofany ki nd This may cause damage to the product Stop using the sensor pa...

Страница 6: ...Jlljack Alarm Speaker Speaker for alarms Inside Battery Box H M l DllayTime Os 11 2s 4s Sal1ct I I I I L iJ 1 5V AA Battery 1 5V AA Battery 1 5V AA Battery I Page 6 of 11 ST710 Control Unit Inside Battery Box continued Volume Switch Alarm volume switch H M L H High volume M Medium volume L Low volume Delay Time Switch Alarm time delay setting to avoid unnecessary alarm caused by patient s tossing ...

Страница 7: ...h switch to set how quickl y an alarm should go off when 4 receiving the signal from a sensor Set the alarm time delay by sliding the time switch to set how quickly an alarm should go offwhen receiving the signal from a sensor Check ifthe ST710 and sensor is working properly See page 10 Testing the System for detail Check ifthe ST710 and the sensor pad are working properly See page 10 Testing the ...

Страница 8: ... By the bedside Alert when patient tries to leave the bed Plug the floor mat sensor cable into the ST710 sensor jack Doing so automatically places the ST7l0 in Floor Mode Removing the floor mat sensor cable from the ST7l0 turns offFloor Mode operation and returns the ST7lOto Bed Mode Chair Mode Make sure the cable will not interfere with the bed wheels or movable bed components and that no one wil...

Страница 9: ...19 B Mounting Attachments The ST710 can be fitted with the following attachments Strap The strap is attached to the ST710 through a strap hole and can be attached to a bed chair or handrail Mounting Clip The ST710 unit can be attached to the wall or chair through a stainless steel wheelchair clip or wall mounting bracket Strap hole Strap Clip mounting unit I D Chair clip Wall mount clip Alarm Indi...

Страница 10: ...ord is securely plugged in 2 Place weight on the sensor pad Make sure the Red LED starts blinking and the alarm sounds 3 Press the Hold button to stop the alarm 4 Press the Hold button again to reset the alarm Page 10 of 11 Troubleshooting Sensor Pad Cannot Detect Movement When the sensor pad cannot detect the patient s movement because she he is too lightweight Try placing the sensor in another p...

Страница 11: ... Mat Sensor resistance less than 3k ohm Size WxDxH 70mm x 27mm x 113mm Water protection classification IPXO Weight 2 Approx 172g 1 24Hrs Alarm 20sec volume max 5 times day 2 Without protective silicon boot with batteries ST710 Instruction Manual 0510 0519 B Page 11 of 11 Accessories The SENSATEC ST710 monitor can be used with the following SENSATEC sensor pad and mats Sensor Pads RFT l000 1801 30 ...

Отзывы: