QUANTAFOB
Relay Outputs
The receiver provides 4 changeover relay switches each capable of switching up to 1.2KW (5A @
230V). Each relay is independent and separately controlled, and can therefore be used to switch most
voltages either ac or dc.
Each output relay provides an isolated switch. Connections are Common (COM), Normally Open (NO)
and Normally Closed (NC).
Installation
Below is a simple example showing one possible way to wire a relay in order to provide switched power to
an external load:
When the relay is energised the ‘COM’ connects to ’NO’ and power is applied to the Load.
1.
Open the enclosure by removing fixing screws from the enclosure
2.
Remove the antenna and slide out the circuit board.
3.
Connect the power supply screw terminals 12-32V ac or dc to the supply terminals.
4.
Wire your desired connections to the relay switches
5.
Once wiring is complete, use the handheld QUANTA transmitter to switch the outputs on and off.
6.
As supplied, the transmitter will operate the outputs - Sw 1 to output 1, Sw 2 to output 2 etc.
7.
Change the output functions to latching, / Momentary Operation.
C
O
M
NO
NC
Relay Connections when
Transmitter NOT Operating
C
O
M
NO
NC
Relay Connections when
Transmitter OPERATING
Relay
Relay
Relay
0
V
L
O
A
D
1
2
V
12V
0V
COM
NO
NC
Supply
Terminals
Receiver