background image

HORNET PRO 

 

DS-HORNETPRO-4 

Advanced Operation 
 
Configuring receivers  
The link pins LK1 and LK2 set the action of the relays 

1

/

2

 sec Mom  

= Relay will operate for 

1

/

2

 sec  

Mom  

= Relay will operate for as long as transmitter switch operated 

Latch  

 

= Relay will toggle ON/OFF on each transmitter button press 

FlipFlop 

= Relays 1 & 2 and 3 & 4 operate in pairs.  

 

 

 

When button 1 is pressed relay 1  switches on, Relay 2 Switches off 

 

 

 

When button 2 is pressed relay 2  switches on, Relay 1 Switches off 

 

 

 

Relay 3 & 4 operate in the same manor to Transmitter buttons 3 & 4.  

12-30V Version 

 

 

LK

1

LK

2

Link Pins

LED

 

s

RF Receive
RF Transmit
LEARN 

1

2

3
4

Link Positions 

Switch relays 

LK1 

LK2 

RLY 1 

RLY 2 

RLY 3 

RLY 4 

Open 

Open 

1

/

2

 sec 

Mom 

1

/

2

 sec 

Mom 

1

/

2

 sec 

Mom 

1

/

2

 sec 

Mom 

Closed 

Open 

Mom 

Mom 

Latch 

Latch 

Open 

Closed 

Mom 

Mom 

Mom 

Mom 

Closed 

Closed 

Latch 

Latch 

Latch 

Latch 

230Vac Receiver 

Link Positions 

Relay Outputs 

LK1 

LK2 

RLY 1 

RLY 2 

Open 

Open 

Mom 

Mom 

Closed 

Open 

Mom 

Latch 

Open 

Closed 

Flipflop 

Flipflop 

Closed 

Closed 

Latch 

Latch 

Note 

When using Keyfobs with “ON” “OFF” set the jumper links to MOM, then the receiver output will 

energise when ON is pressed and relax when OFF is pressed 

Содержание FOBBER-8T6

Страница 1: ... to Go Description A versatile general purpose Remote Control System for many different applications Housed in a rugged IP68 weatherproof enclosure The new HORNETPRO system is ide ally suited to any remote switch requirement With upto 4 changeover Relay switch outputs each output can be controlled from any switch on any transmitter Additional transmitters may be added to the system using the same ...

Страница 2: ...for further info Range stated is optimum direct line of sight In worst conditions this can be reduced by over 50 Part Number Description Range FOBBER 8T1 1 Sw 200m FOBBER 8T2 2 Sw 200m FOBBER 8T3 3Sw 200m FOBBER 8T4 4 Sw 200m FOBBER 8T6 4 ch 6 Sw 200m FOBBER 8T8 8 Sw 200m FOBBER 8TL1 2 button 1ch ON OFF 200m FOBBER 8TL2 4 button 2ch ON OFF 200m Part Number Description Power Supply HORNETPRO 8R4 4 ...

Страница 3: ...Load 1 Open the enclosure by removing fixing screws from the enclosure 2 Remove the antenna and slide out the circuit board 3 Connect the power supply screw terminals 4 Wire your desired connections to the relay contact outputs 5 As supplied the handheld will operate the outputs switch1 to output1 switch2 to output2 etc 6 Set the output functions to latching Momentary Operation COM NO NC Relay Con...

Страница 4: ...ff Relay 3 4 operate in the same manor to Transmitter buttons 3 4 12 30V Version LK1 LK2 Link Pins LED s RF Receive RF Transmit LEARN 1 2 3 4 Link Positions Switch relays LK1 LK2 RLY 1 RLY 2 RLY 3 RLY 4 Open Open 1 2 sec Mom 1 2 sec Mom 1 2 sec Mom 1 2 sec Mom Closed Open Mom Mom Latch Latch Open Closed Mom Mom Mom Mom Closed Closed Latch Latch Latch Latch 230Vac Receiver Link Positions Relay Outp...

Страница 5: ... Receiver only To pair a new transmitter switch follow this procedure Unscrew the antenna Open the enclosure and extract the Circuit board assembly 1 Briefly press the receiver LEARN switch once 2 The Learn LED will flash once One flash means the receiver unit is ready to allocate a transmitter to relay output 1 3 To select relay output 2 3 or 4 briefly press the LEARN switch again and repeat unti...

Страница 6: ...mperature 10 to 50o Celsius The relay contacts in this unit are for functional use only and must not be used for isolation purposes Electrical Characteristics Min Typical Max Units Supply Voltage 2 9 3 3 3 V Supply Current 17 mA Frequency 433 92 869 50 MHz RF Output Power ERP 10 mW RF Bandwidth 60 KHz Electrical Characteristics MIN TYPICAL MAX DIMENSION Supply Voltage for Low Voltage version 11 32...

Страница 7: ...HORNET PRO DS HORNETPRO 4 50 00 59 00 46 00 82 00 10 00 All Dimensions in mm 3 x slots 4 5 x 13mm Mechanical Dimensions 76 80 4 20 96 100 Measurements in mm drawing not to scale ...

Страница 8: ...RF Solutions Limited et käesolev raadioseadme tüüp määratletud selles dokumendis vastab direktiivi 2014 53 EL nõuetele ELi vastavusdeklaratsiooni täielik tekst on kättesaadav järgmisel internetiaadressil www rfsolutions co uk FI RF Solutions Limited vakuuttaa että radiolaitetyyppi määratletud selles dokumendis on direktiivin 2014 53 EU mukainen EU vaatimustenmukaisuusvakuutuksen täysimittainen tek...

Отзывы: