(T) Data Timeout
The data timeout is the period of time without serial data. The radio uses this value to determine that the
data transmission has finished.
The default value is 10.
The following text is displayed:
Enter Data Timeout (0-3000) milliseconds: 10
Serial Port Configuration Menu
This menu allows the configuration for the serial port parameters for both the Main and Auxiliary ports.
The menu screen is shown in Figure 10.
***
Port Selection Menu
***
Main Port:
19200 Baud, No Parity, 8 Data, 1 Stop, No Flow
Main Port:
Packet Timers: Output = Disabled, Input = Disabled
Aux
Port:
19200 Baud, No Parity, 8 Data, 1 Stop, No Flow
Aux
Port:
Packet Timers: Output = Disabled, Input = Disabled
(M)
Main Port
(A)
Aux
Port
(Esc)
Previous Menu
Enter Choice:
Figure 10: Serial Port Configuration Menu
The Main Port may require configuration for compatibility with the existing machinery. Select ‘M’ to reveal
the menu shown in Figure 11. The options are explained below.