© Copyright 2003-2005 RF Code, Inc. All rights reserved. UM-C2020-R05-20030422.
No copying of this material is allowed without prior written permission. Page 16 of 28.
16
USER MANUAL – Mantis™ II Reader
(A)RP Table Display
A
A – Display ARP Table.
•
When two or more Readers initially share the same IP address, it is
likely that the ARP will need to be either modified or flushed before
sequential accesses to the same IP address can be performed (due to
physical addressing). This feature provides a method of querying the
ARP table to assess IP resolution issues.
Advanced Network Settings
(1) Keep Alive Probes (default = 10)
1
1 – Change number of keep-alive probes.
•
Defines the maximum number of keep-alive probes to send.
•
An error message is displayed if an invalid number is entered (and
the field will be cleared).
(2) Keep Alive Signal Interval (default = 1000 ms)
2
2 – Change keep-alive signal interval.
•
Defines the signal interval (in milliseconds) for how often the keep-
alive probes are sent on a connection.
•
An error message is displayed if an invalid number is entered (and
the field will be cleared).
(3) Packet Size (default = 1400 bytes)
3
3 – Change packet size.
•
Defines the maximum packet size (in bytes).
•
An error message is displayed if an invalid number is entered (and
the field will be cleared).
(4) Packet Timeout (default = 500 ms)
4
4 – Change packet timeout setting.
•
Defines the packet timeout (in milliseconds).
•
An error message is displayed if an invalid number is entered (and
the field will be cleared).