20
USER MANUAL – Mantis™ II Reader
Ethernet Settings
As shipped, the default network settings for the
Mantis™ II Reader
are:
IP address:
192.168.1.129
Subnet mask: 255.255.255.0
Gateway:
192.168.1.5
U
WARNING – These settings must be changed to match the subnet of
the network on which the Mantis™ II Reader is to be used.
These Ethernet settings are stored in the network.txt file, which is read by
the Reader at boot time. Each setting is represented as a string of
hexadecimal characters. For IP addresses, a pair of hexadecimal characters
(00 to FF) represents each decimal component (0 to 255) of the address. For
example:
IP address:
192.168.1.239 =>
C0A801EF
Subnet mask: 255.255.0.0 =>
FFFF0000
Gateway:
192.168.1.1 =>
C0A80101
The network.txt file consists of the following default hexadecimal strings
that are concatenated on a single line. For example:
C0A80181 FFFFF000 C0A80105
0A
3E8
578
1F4
IP Address
Subne
t
Mask
Gate
way
Keep
-Al
iv
e
Probes
Keep
-Al
iv
e
Interval
(m
s)
Packe
t
Size
(by
te
s)
Packe
t
Timeou
t
(m
s)
U
WARNING – This network.txt file should not be altered. Instead, the
Network-Enabled Reader Programmer Utility allows the user to
change these settings using dotted decimal notation for IP
addresses, the subnet mask, and other advanced settings.
Содержание Mantis II