Reznor, AB - 2 Gas, GB 2019-08, D301177 Issue A PAGE 3
Technical Specification
Model : Air Curtain AB xxxx-2
AB 225N
AB 175N
AB 225N
AB 175N
AB 225P
AB 175P
Natural gas G20 (I2H)
Natural gas G25 (I2L)
PropaneG31 (I3P)
Gas Connection
¾ inch external thread
Maximum Supply Pressure (mbar)
25
30
45
Minimum Supply pressure (mbar)
17
20
25
Nominal pressure (mbar)
20
25
37
Gross heat input (kW)
66
45,5
66
45,5
65
45,5
Nett heat input (kW)
59.4
41.0
59.4
41.0
60.2
41.0
Nett heat output (kW)
54.0
37.0
54.0
37.0
54.8
37.0
Gas flow rate (m³/uur)
6.3
4.3
7.4
4.3
-
-
Gas flow rate (kg/h)
-
-
-
-
4.6
3.2
N° of injectors
5
Injector size (mm)
Ø3.4
Ø2.9
Ø3.4
Ø2.9
Ø1.85
Ø1.60
Injector pressure (mbar)
7.25
6.35
10.90
9.30
30.50
26.00
Flue nominal bore (mm)
130
I/D fan
Voltage
230 V 1-fasig 50 Hz
Power Rating
120 W
Current
0,9 A (FLC)
Air Distribution Fans
Type
Centrifugal (with integral thermal trip)
Speeds
2
N° of fans
4
3
4
3
4
3
Max. air volume
11000m3/hr (AB 175)
13000m3/hr (AB 225)
Voltage
230V 1PH 50Hz
Power rating (per fan)
1140 W
Current (per fan)
5.2A (FLC)
Start current (per fan
11A
Constitution
Model
AB175-2
AB225-2
AB350=
X 2
AB400=
X 1
X 1
AB450=
X 2
AB525=
X 3
AB575=
X 2
X 1
AB625=
X 1
X 2
AB675=
X 3
WARNING: