II&E2020_11
Hi-Finity electric lock: Installation and testing
– Manual for the installer & electrician 14
3.3 Onsite completion mechanical installation
3.3.1 Assembly of the connection rod
For both assembly options (standard
062.9551.--
or pre-motor
062.8259.--
), the
connection rod has the same principles on installation.
!
Check if the lock is connected to the power supply, a button and is working before
installing the connection rod.
▲
1
Remove the stopper and slide the glass pane completely to open position.
▲
2
Slide the rod into the top U-profile hooked into the drop bolt
▲
3
Move the glass pane until fully closed position.
▲
4
Insert the connection piece into the vertical side U-profile via the openings.
▲
5
Fasten the rod with the bolt until it is fixed.
▲
6
Fine tune the connection piece (see next step).
3.3.2 Fine-tune the rod
▲
5
The drop bolt should be down. The drop bolt will not go down when 1) the magnet is
not aligned 2) it touches the rod.
▲
6
Fine-tune the rod position by using the screw.
The sliding window should have some tolerances in both directions.