REFUdrive 500 RD51
Electrical installation
3-7
DOK-RD500*-RD51*******-IB01-EN-P
Terminal layout diagram, sizes B - E
A drive converter, size C (270 mm wide) is illustrated in the terminal lay-
out diagram. The terminal position is the same for narrower or wider units.
Line supply-, DC- and brake resistor connections are always at the top
and the motor connections at the bottom in the housing.
Note:
The P24V electronics standby power supply (terminal X83) is
only installed if this was specified when ordering. It may only
be retrofitted by our service department.
X1
X2
Motor connection
X83
OPTION P24V Electronic stand-by
Control- and
signal cables
Supply connection,
DC link connection,
Brake resistor connection (option)
PE
W2
V2
U2
C D F
on
on
ready
ready
alarm
alarm
Esc
Start
Mon
Stop
Prog
Enter
W1
V1
U1
Abb. 3-3: Terminal layout diagram size B - E