8
10. Replace the hold-down plate (5), screw
the eight hex bolts (4) in, but do not
tighten. (Fig. 16)
11. Place the blade setting gauges (7) on
the cutterhead with both gauges resting
firmly against the blade. (Fig. 17)
12. Turn both of the adjusting screws (8)
until the blade touches the blade setting
gauges (7). (Fig. 17)
13. Remove the blade setting gauges and
then rotate the cutterhead to expose the
eight hex blots (4). Tighten all bolts with
supplied wrench. (Fig. 16)
14. Replace the dust cover and secure it
with the two screws.
15. Replace the dust collector.
NOTE:
The thicknesser will not start until
the dust cover is properly installed.
REPLACING CARBON BRUSHES (FIG. 18)
The carbon brushes furnished will last
approximately 50 hours of running time,
or 10,000 ON/OFF cycles. Replace both
carbon brushes when either has less than
6.35 mm length of carbon remaining, or if
the spring or wire is damaged or burned. To
inspect or replace brushes, first unplug the
tool. Then remove the black plastic cap (1)
on the side of the motor (2). Remove the
cap cautiously, because it is spring-loaded.
Then pull out the brush and replace.
Maintenance
Replace for the other side. To reassemble
reverse the procedure. The ears on the
metal end of the assembly go in the same
slots the carbon part fits into. Tighten the
cap snugly, but do not overtighten.
NOTE:
To reinstall the same brushes, first
make sure the brushes go back in the way
they came out. This will avoid a break-in
period that reduces motor performance and
increases wear.
REPLACING V-BELT
Inadequate tension in the V-belt will cause
the belt to slip from the motor pulley or drive
pulley. A loose belt must be replaced. To
replace V-belt:
● Turn thicknesser OFF and unplug from
the power source.
● Loosen and remove screws on right
panel.
Remove the panel.
● Remove old belt by walking the belt from
motor and drive pulleys alternatively.
Gently pull the belt while turning the
pulleys at the same time.
● Replace with new belt. Walk the belt
onto the pulleys in the reverse manner
as when removing the belt.
● Make sure the belt is evenly seated all
the way on the motor and drive pulley
grooves.
● Replace and secure right panel.
LUBRICATION
● Motor and cutterhead bearings are
sealed and need no lubrication.
● Gears and elevation screws should be
cleaned of debris and grease
● The tables can be coated with a
lubricant such as
furniture wax, to make
the workpiece feed smoother. Make
sure the lubricant used does not affect
the ability to finish the workpiece with
varnish, sealer, etc. Do not use any
silicone-base lubricants.
CLEANING THE THICKNESSER
Keep thicknesser clean. After 10 hours of
operation, remove wood chips, dust, dirt
and debris.
WARNING!
Never put lubricants on the
blade while it is spinning. To avoid fire or
toxic reaction, never use gasoline, naphtha
acetone, lacquer thinner or similar highly
volatile solvents to clean the thicknesser.
To avoid injury from unexpected starting
or electrical shock, unplug the power cord
before working on the tool. For your safety,
this tool is double-insulated. To avoid
electrical shock, fire or injury, use only parts
identical to those identified in the parts
list. Reassemble exactly as the original
assembly to avoid electrical shock.
Содержание AP3300
Страница 1: ...1 GB 13 IN 330 MM BENCH THICKNESSER AP3300 INSTRUCTION MANUAL...
Страница 2: ...2 CONTENTS GB P 1 8 The original instruction manual is in English...
Страница 14: ...11 Fig 16 Fig 18 Fig 17 Fig 14 4 3 4 6 5 8 7 Fig 15 1 2 1 2...
Страница 16: ...13 MODEL AP3300 Schematic A...
Страница 18: ...15 Schematic B MODEL AP3300 MANUAL INSTRUCTION...
Страница 20: ...17...