a. Saving a scene

 

 
 
A scene must have been defined in a 
two-step process before it can  be 
stored.  
 
 

Step 1 

To start with, you define through 
Setup  –  Scene,  which rooms are 
involved and which are not. 
 
Essentially, there are three room 
statuses when defining the scene: 
 
1.  The room is actively switched on 

when the scene is called if it was 
switched off at the time or it 
remains switched on.  

 
The room is an active element of the 
scene  

 

Room included:  YES 

 
 
 
2. The room is actively switched off 

when the scene is called if it was 
switched on at the time or it 
remains switched off.  

 
The room is an active element of the 
scene  

 

Room included:  YES 

 

 
 
 
3.  The room retains its status (on or 

off) when the scene is called.  

 
The room is not an active element of 
the scene, i.e. it remains passive. 

 

Room included:  NO 

 
This is an advantage, if it should be 
guaranteed that the person in the 
corresponding room can decide 
independently whether music should 
be played or not. 
 
Scene example: 
Coming home 
 
If only the rooms 

Hallway

 and 

Lounge

 

were selected for a scene Coming 
home  and all others were switched 
off, it could happen that music being 
played by persons who were already 
in the house is switched off.  
 
 
With the Store softkey, you reach the 
level where the classification of 
Included YES  or  Included NO  is 
made. 
 

 

 

Содержание Re:system M10

Страница 1: ...1 as82 of of E 2 07...

Страница 2: ......

Страница 3: ...iew M10 Connection Panel Connection Panel Description Ethernet Interface M10 Setup Ethernet Setup Source Setup Remote Setup Scene function Version Control Guarantee Scope of delivery Disposing of your...

Страница 4: ...populated with modules These modules cover a whole range of options from an analogue record deck right up to a future safe network connection to the Worldwide Web The modular approach which Revox has...

Страница 5: ...and has no ground For this reason the unit is particularly well iso lated and must pass a strict insulation test This guarantees that even if the neutral line is broken no accessible part of the unit...

Страница 6: ...measures Unusual operation Unplug the unit from the mains immediately in the event of any unusual noises or odours Have the unit checked by your dealer without delay Do not open the unit The unit may...

Страница 7: ...ween the M10 and the built in rack Regulations pertaining to the unit In EU and EEC countries Revox offers a guarantee on units bought in the EU over and above the statutory rights of guarantee claims...

Страница 8: ...ew M10 Rear view Note Slots A1 and A2 may only be populated with second generation modules that have been developed since the start of 2008 These can be identified by the following symbol on the back...

Страница 9: ...e it in the 19 cabinet in the best possible way See the figure below The M10 can be installed with the plug in slots directed to the front or the back See figure on Page 9 Depending on the cabling str...

Страница 10: ...oth sides of the M10 2 Now the retaining bracket is moved from the front to the back in the corres ponding position 3 All 6 screws are then screwed back in as shown in the figure Please note Also the...

Страница 11: ...M10 Re system 9 M10 Installation in a 19 cabinet Sectional view of a 19 cabinet with installed M10 A M10 retaining bracket forward spaced B M10 retaining bracket inserted...

Страница 12: ...Mains connection with fuse Operational display LED green blue Error display LED red LAN Ethernet connection USB B connection for PC RS232 onlyforfirmwareupdates SD card slot software update M Link fo...

Страница 13: ...ting at 200 240 V Note The M10 mains supply is fitted with a non grounded rubber connector For this reason only the supplied mains cable may be used Power LED There is an operational display LED both...

Страница 14: ...ts software correct for each slot LAN Ethernet connection A connection to an Ethernet LAN can be established through the RJ45 socket The Ethernet interface is configured manually during the M10 setup...

Страница 15: ...indows message appears on the screen that a new device has been recognised with the name Revox M10 USB Link The corresponding driver must be installed to set the unit up See next chapter Installing th...

Страница 16: ...which various Revox interfaces can be connected to e g M200 Domotic interface M201 IR interface etc Both the RJ11 sockets are electrically parallel switched You should only use a non crossed 4 core t...

Страница 17: ...control softwares can be found on the Revox Homepage As well as operation through the Revox service programs the M10 also offers the option to influence the Revox Multiroom System and or to let feedb...

Страница 18: ...n to other Revox application like M203 M232 etc over TCP you should use different ports for them TCP always will use port 5524 Therefore you should use for your UDP tasks the following other ports 403...

Страница 19: ...r You will find an overview of a possible Ethernet network on the next page The defined IP addresses are only examples and must be modified to meet the needs of the particular installation DHCP is not...

Страница 20: ...M10 Re system 18 Functional plan The IP addresses shown above are only examples andmust be modified to meet the needs of the particularinstallation...

Страница 21: ...ew the main menu shown below for the M10 setup can be called with the setup key The Setup menu appears as follows if the Multiroom module is installed Ethernet Setup The Ethernet setup is reached thro...

Страница 22: ...t required for the radio transmission does not appear with its IP address in the CLIENT LIST Page TCP IP The base settings for the Ethernet access are set through the two TCP IP pages The setting is m...

Страница 23: ...not given the M10 s IP IP Subnet Mask The 4 blocks of the IP Subnet that the M10 should have are set using the two Mask softkeys Default Gateway The 4 blocks of the Default Gateway that defines the ex...

Страница 24: ...Here you can enter the target address if the UDP packet should only be sent to one specific recipient Using the setting 255 255 255 255 the data packet is sent in Broad cast mode to all who have opene...

Страница 25: ...r Important So switching is automatically recognized a CR carriage return must be sent before any M Text command Source Menu Using the Source softkey you can access the setup menu for the plug in modu...

Страница 26: ...nstallation the Tuner key calls the FM Tuner on the tuner module while with another it calls the SAT tuner from the satellite module In general you can say that variables defined through the Remote me...

Страница 27: ...hen you select the key variable Remote button from an operating unit Once this is set this is assigned to a specific source Select zone To start with you select the Multiroom zone with the Zone softke...

Страница 28: ...voided The TV button must be disabled if using TV Hold otherwise TV Hold is ineffective The TV button is only available with remote controls but not with wall mounted keypads Select source Using the t...

Страница 29: ...FM Tuner is selected with the Tuner Remote button In Zone 3 on the other hand the SAT input of the SAT module is activated with the button variable Tuner Note If several modules of the same type e g T...

Страница 30: ...required Remote button through the Zone Button combination and press the Disable softkey The Store softkey then appears that you need to press to confirm your change If you don t press Store the orig...

Страница 31: ...io side Linking the Revox scene with for example a light or window blind scene is done through the building control software Select the Scene softkey in the Setup main menu A total of 16 scenes are av...

Страница 32: ...the time or it remains switched off The room is an active element of the scene Room included YES 3 The room retains its status on or off when the scene is called The room is not an active element of t...

Страница 33: ...case of an M10 installation the speaker integrated in the M10 is defined as the main room Defining additional rooms You change the status of the additional room between Yes and No with the Rooms soft...

Страница 34: ...of the rooms individually and configure them according to your own discretion In this way the optimum volume can quickly be defined by listening Of course it is also possible to configure each room fr...

Страница 35: ...Text protocol for building control offers a further option for calling a scene You will find an exact description of this in the M Text protocol description on the Revox homepage www revox de or www...

Страница 36: ...ftkeys are used to position the cursor left right in the text field Delete Pressing this softkey deletes the characters at the current cursor position Insert Pressing this softkey inserts a character...

Страница 37: ...al and external M10 modules The middle column defines each module the development generation of this module and whether it is bootloader enabled bootloader enabled not bootloader enabled The righthand...

Страница 38: ...posal of your old device helps to avoid negative impacts on the environment and on personal health Scope of delivery Re system M10 Operating manual Power cable USB cable TORX screwdriver Installation...

Страница 39: ...ight 171 mm corresponds to 4 RU 6 73 inch Weight 11 0 kg 24 25 lb without packaging and accessory box Permitted ambient temperature 0 50 C 32 122 F Power consumption Standby 2 W Operation 4 160 W Depe...

Страница 40: ...M10 Re system 38 Re system M10 Operating Instructions Part No 10 30 3084...

Отзывы: