![Revox Re:system M10 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/revox/re-system-m10/re-system-m10_user-manual_1448999014.webp)
M10
Re:system
12
LED red – flashing
quickly
A) Temperature is too high
There is overheating in the M10
housing. The maximum permitted
temperature value has been exceeded
even though the fan is active.
Countermeasure(s):
- Check the installation
environment
- Check the ventilation slots
- Check the fan
B) Power levels are too high
The permitted power value has been
exceeded at one or more of the
internal M10 power units.
Countermeasure(s):
Check the connected cables (M-Link,
USB, etc.) for short circuits.
Are all modules inserted correctly in
the M10?
C) Software problem
There is a fault in the data traffic.
Countermeasure(s):
- Carry out a firmware update
- Check the modules. Is the module
type and its software correct for
each slot?
LAN Ethernet connection
A connection to an Ethernet LAN can
be established through the RJ45
socket. The Ethernet interface is
configured manually during the M10
setup. DHCP functionality is not
supported.
The two LEDs integrated in the RJ45
socket indicate the status of the data
connection.
The Revox Multiroom System can be
controlled through the Ethernet
interface. Either through the Revox
Service programs, e.g. M230 or the
primary domestic control system, e.g.
GIRA Home Server.
There is a very flexible UDP protocol
available for domestic control system
programmers.
Further information about this clear-
text protocol can be found under
www.revox.de
A maximum of 10 Clients can have
parallel access to the M10. The MAC
address is noted on the bottom of the
M10.
You will find further documentation
about the Ethernet interface starting
from Page 16
.