1200-000002 r04                                                                                                        2                                                                    UPDATED   10/25/2022 

 

Product Contents

 

 

 

3. 

 

4. 

CAUTION

: DO NOT cut through the protective 

storage box to avoid any damage to the device. 

1.

 

Carefully cut the tape covering the shipping box to not 
damage the storage box inside. 

2.

 

Remove the storage box from the shipping box. 

 

Cut the tape dots located on the sides of the 
storage box.  

3.

 

Open the one seal on the storage box to reveal the Cap 
and support base. 

4.

 

Lift the support base to reveal the accessory kit. 

 

 

5.

 

Remove the accessory kit and carefully read the Quick 

Start Guide on the box lid or in the app manual. 

6.

 

Remove the accessories contained inside the accessory 
kit:  

 

USB-to-Magnetic Micro-USB cable 

 

Travel Bag 

 

AC Adaptor  

 

Adjustment Headliners 

7.

 

Charge the Cap for at least one hour prior to use with 

the AC adaptor and magnetic micro-USB cable. 

 

 

 

 

 

 

5. 

 

Adjusting the Cap

 

The Cap comes with front standard and back 10mm headliners 
installed as illustrated below. The Cap should not be loose 
enough that it falls off the head with ease, nor should it fit too 
tightly. A proper fitting Cap is an important step for a reliable 
treatment.  

                       

 

           NOTE: Light emitting area (emission aperture) shown above. Applied Part.  

 

To Adjust Headliners: 

1.

 

A sensor detects when the Cap is on the head and 
close to your forehead. If the Cap needs adjustment, 
remove the 10mm back headliner from the headliner 
dots. If loose, replace with the optional 20 or 30mm 
back headliner. If tight, replace with the optional 
standard back headliner.   

 

2.

 

Fit test: press the Cap against your forehead. If a 
pinky finger can still fit between the Cap and the 
back of your head, then the Cap is too loose.  

 

 

 

 

NOTE: To ensure proper sensor connection, the thick headliners 

should only be used in the back of the Cap. The front headliner is 

only to be replaced for sanitary purposes. For consistent fit and 

wear, it is suggested to replace headliners every three months. 

Replacement headliners can be ordered at REVIAN.com.  

 

 

 

 

 

 

 

Содержание RED 101

Страница 1: ...he counter medical device operated via mobile app to promote hair growth REVIAN RED is intended for a daily 10 minute treatment A treatment can be paused after it is initiated the remaining treatment...

Страница 2: ...tandard and back 10mm headliners installed as illustrated below The Cap should not be loose enough that it falls off the head with ease nor should it fit too tightly A proper fitting Cap is an importa...

Страница 3: ...s when the Cap is properly placed on your head Place the Cap on your head to activate the sensor or put your finger over the sensor located in the forehead area of the cap Press the CONNECT YOUR CAP b...

Страница 4: ...again on your head and it will automatically pick up where it left off Only a single 10 minute treatment can be initiated daily Time remaining will be displayed on the mobile app screen Another treatm...

Страница 5: ...ht will softly flash every 4 seconds When the cap is charging the app is not connected and will not provide a battery level To determine the battery level disconnect the charging cable from the cap an...

Страница 6: ...during support tickets to help troubleshoot any issues you may be having with the app SUPPORT In the Troubleshooting section you can find answers to commonly asked questions and troubleshoot issues If...

Страница 7: ...Messages and sound signals during use The mobile app will display messages on occasion These will appear as direct messages or icons in the mobile app App Messages Check Bluetooth This message appear...

Страница 8: ...ice and not the Cap Check mobile device settings and ensure device isn t already paired with another device The mobile app is not scanning for the Cap Force the mobile app to scan for the Cap by tappi...

Страница 9: ...revian com or on the website at revian com support PROBLEM POSSIBLE CAUSE SOLUTION The mobile app will not download firmware or software updates The cloud server is unavailable The device software is...

Страница 10: ...te blue The charging cable connector will illuminate blue always when connected to AC power The battery should be charged from a depleted state to a full charge within 4 hours The battery will have en...

Страница 11: ...of cleaning agents or solvents are not recommended and may damage the REVIAN RED Cap The battery is rechargeable but not intended as a user replaceable part Use the Cap only as intended and described...

Страница 12: ...everse hair loss The approximate size of the Cap is Height 15 87 cm 6 25 in x Width 20 cm 7 87 in x Length 22 86 cm 9 in Weight 155 g 0 34lbs How is the REVIAN RED Cap shipped After order completion t...

Страница 13: ...d I attach headliners The recommended headliners not only ensure proper fit of the Cap but they also provide additional comfort and help maintain cleanliness Is this a use it or lose it treatment plan...

Страница 14: ...Compliance Electromagnetic Environment Guidance RF emissions CISPR 11 Group 1 REVIAN RED uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cau...

Страница 15: ...quality should be that of a typical commercial hospital or home healthcare environment Surge IEC 61000 4 5 1 kV line s to line s 2 kV line s to earth PASS Mains power quality should be that of a typic...

Страница 16: ...manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site surveya should be less than the compliance lev...

Страница 17: ...as recommended below according to the maximum output power of the communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 k...

Страница 18: ...een the REVIAN mobile application running on an iOS or Android operating system and REVIAN cloud services as well as between the REVIAN app and the REVIAN RED Cap Figure E1 Communications of treatment...

Страница 19: ...energy and if not used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular instal...

Отзывы: