REVIAN RED 101 Скачать руководство пользователя страница 11

1200-000002 r04                                                                                                        11                                                                    UPDATED   10/25/2022 

 

Learn More

 

3.  RECOMMENDED USAGE 

 

Use the Cap daily, for 10 minutes at any convenient time.  

 

Use indoors or in a cool, dry area. This product is not 
intended for exposed use outdoors. 

 

Use only on dry or towel dried hair. 

 

If REVIAN RED treatments are stopped for several weeks or 
more, natural hair loss may resume. 

 

Commit to disciplined daily use and be patient, as it may 
take a full hair cycle of 16-26 weeks to achieve initial results. 

 

Patient is the intended operator of this device. 

 

REVIAN RED is not a defibrillation proof device.  

4.  WARNINGS AND CAUTIONS 

 

 

5. 

 

   

WARNINGS

 

 

DO NOT use the USB-to-micro-USB cable or 

AC adaptor if either are damaged. 

 

DO NOT use the Cap or AC adaptor if either 

has been exposed to water. Visit 

revian.com/support/ 

 for additional 

information.  

 

DO NOT place the Cap or support base in or 

near water. If exposed to water unplug the 

device immediately from the power outlet.  

 

DO NOT reach into water to retrieve the 

device while plugged into an outlet. 

 

DO NOT use the Cap while in the bathtub or 

the shower. 

 

DO NOT use the Cap if you are taking 

photosensitizing medications, shampoos, 

lotions, or other therapies that sensitize the 

skin to light. Consult your physician 

regarding use in these conditions. 

 

DO NOT use with wet hair. 

 

DO NOT insert foreign objects into micro-

USB receptacle on top of the Cap (Water 

resistant to IP22 standards).   

 

DO NOT use any cables, adaptors, or 

products that are not provided or approved 

for the device as this may result in non-

compliance.  

 

DO NOT use any cables, adaptors, or 

products that are not provided or approved 

for the device, as they may negatively 

interfere with the EMC performance.  

 

Interference may occur with other electrical 

equipment near the REVIAN RED Cap due to 

the use of mobile Radio Frequency (RF) 

communications. 

 

The Cap has NO user-serviceable parts and 

any attempt to remove internal components 

will void the warranty and may cause harm 

to the user.  

 

  

16. 

 

7. 

 

8. 

 

   

CAUTIONS

 

 

If the REVIAN RED Cap meets water, 

humidity, or excessive perspiration, allow to 

dry before use, charging or storage. 

 

Use of cleaning agents or solvents are not 

recommended and may damage the REVIAN 

RED Cap.  

 

The battery is rechargeable but not 

intended as a user-replaceable part. 

 

Use the Cap only as intended and described 

in the application instructions. Any attempt 

to bypass the approved mobile app or 

hardware will void the warranty. 

 

If pregnant or nursing, consult your primary 

care physician regarding use of the Cap in 

these conditions.  

 

Keep the Cap out of reach of children and 

pets.  

 

The Cap is to be operated at a temperature 

of at least 15˚C (59˚F).  

 

Use of the Cap is intended for a single 

registered user.  

 

Keep the micro-USB port cover located on 

top of the Cap closed when not charging.  

 

BATTERY: Risk of Fire and Burns. Do Not 

Open, Crush, Heat Above 100˚C or 

Incinerate. Follow Manufacturer's 

Instructions. 

 

Do not look directly into LED lights.

 

 

5.

 

LIMITED WARRANTY 

 

The Company warrants that this Device will be free from manufacturing 
defects in material and workmanship for a period of twelve (12) months from 
the date of delivery. The Company does not warrant that the operation of 
the Device will be error-free or uninterrupted. The user is responsible for the 
proper maintenance and handling of the Device. No warranty is extended 
to any Device that has been altered, physically damaged, or modified in 
any way. The limited warranty does not cover problems caused by user acts 
(or failures to act), the acts of others or event(s) beyond the reasonable 
control of the Company. 

If Device fails to meet the warranty set forth above, then the Company will, 
at its option, either (i) repair the defective Device, (ii) provide a free 
replacement Device or (iii) replacement parts. Any replacement Device or 
part will be comparable in function but may not be identical to the original. 
The replacement or repaired Device is warranted for the remainder of the 
original warranty period. 

If the Device or any component thereof is defective or otherwise does not 

function properly within the Limited Warranty period (as defined above), 

contact the Company at www.revian.com/support/ to submit a Warranty 

claim. All returns must be authorized by the Company prior to receipt. Once 

a return is authorized, the Company will issue a Return Merchandise 

Authorization (RMA) number and provide instructions on how to return the 

Device.

 

 

 

 

  

 

     

 

 

 

 

 

Содержание RED 101

Страница 1: ...he counter medical device operated via mobile app to promote hair growth REVIAN RED is intended for a daily 10 minute treatment A treatment can be paused after it is initiated the remaining treatment...

Страница 2: ...tandard and back 10mm headliners installed as illustrated below The Cap should not be loose enough that it falls off the head with ease nor should it fit too tightly A proper fitting Cap is an importa...

Страница 3: ...s when the Cap is properly placed on your head Place the Cap on your head to activate the sensor or put your finger over the sensor located in the forehead area of the cap Press the CONNECT YOUR CAP b...

Страница 4: ...again on your head and it will automatically pick up where it left off Only a single 10 minute treatment can be initiated daily Time remaining will be displayed on the mobile app screen Another treatm...

Страница 5: ...ht will softly flash every 4 seconds When the cap is charging the app is not connected and will not provide a battery level To determine the battery level disconnect the charging cable from the cap an...

Страница 6: ...during support tickets to help troubleshoot any issues you may be having with the app SUPPORT In the Troubleshooting section you can find answers to commonly asked questions and troubleshoot issues If...

Страница 7: ...Messages and sound signals during use The mobile app will display messages on occasion These will appear as direct messages or icons in the mobile app App Messages Check Bluetooth This message appear...

Страница 8: ...ice and not the Cap Check mobile device settings and ensure device isn t already paired with another device The mobile app is not scanning for the Cap Force the mobile app to scan for the Cap by tappi...

Страница 9: ...revian com or on the website at revian com support PROBLEM POSSIBLE CAUSE SOLUTION The mobile app will not download firmware or software updates The cloud server is unavailable The device software is...

Страница 10: ...te blue The charging cable connector will illuminate blue always when connected to AC power The battery should be charged from a depleted state to a full charge within 4 hours The battery will have en...

Страница 11: ...of cleaning agents or solvents are not recommended and may damage the REVIAN RED Cap The battery is rechargeable but not intended as a user replaceable part Use the Cap only as intended and described...

Страница 12: ...everse hair loss The approximate size of the Cap is Height 15 87 cm 6 25 in x Width 20 cm 7 87 in x Length 22 86 cm 9 in Weight 155 g 0 34lbs How is the REVIAN RED Cap shipped After order completion t...

Страница 13: ...d I attach headliners The recommended headliners not only ensure proper fit of the Cap but they also provide additional comfort and help maintain cleanliness Is this a use it or lose it treatment plan...

Страница 14: ...Compliance Electromagnetic Environment Guidance RF emissions CISPR 11 Group 1 REVIAN RED uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cau...

Страница 15: ...quality should be that of a typical commercial hospital or home healthcare environment Surge IEC 61000 4 5 1 kV line s to line s 2 kV line s to earth PASS Mains power quality should be that of a typic...

Страница 16: ...manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site surveya should be less than the compliance lev...

Страница 17: ...as recommended below according to the maximum output power of the communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 k...

Страница 18: ...een the REVIAN mobile application running on an iOS or Android operating system and REVIAN cloud services as well as between the REVIAN app and the REVIAN RED Cap Figure E1 Communications of treatment...

Страница 19: ...energy and if not used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular instal...

Отзывы: