WIRE SIZE FOR WIRING
WARNING: forbid to overload operation for a long time!
Power
Heater power [kW]
Main line [mm ]
2
Earth line
[m ]
2
SINGLE PHASE ( 230V~, MAIN LINE : L, N)
3
4
5
6
8
10
14
1.5
2.5
2.5
4.0
6.0
10
10
0.75
1.0
1.0
1.5
2.5
2.5
4.0
3.
INSTALLATION
3.1.
GENERAL PRINCIPLES
The following figures show the recommended distances between the air curtain
and the building partition
:
The width of the curtain should be greater or equal to the width of the door frame.
When the entrance is wider than the unit, it is recommended to install two or more
units in parallel. In this case, provide 10-40 mm gaps between the units
.
3.2.
ASSEBLY “STEP BY STEP”
The curtain can be assembled on wall or ceiling. If any components are not included
in the kit, you should buy them yourself and make sure they are suitable for this
type of installation
.
a)
wall mounting
-
unscrew the fixing screws to remove the mounting plate from the back of the
main body
-
install mounting plate on the wall
4.1.
CONNECTION OF THE DEIVCE TO THE ELECTRICAL SYSTEM
- all works concerning electrical installation should be made by the qualified
personnel (who possess required authorizations to install electrical equipment),
based on wiring schematic diagrams. (see 7)
-
the electrical installation of the building shall have a residual current device
-
check the electrical installation and automation before the first start
5.
PRECAUTIONS AND WARNINGS
During operation of the device, the following must be respected:
-
all works concerning electrical installation (disassembly, repair etc.) should be
made by the
qualified personnel, who possess the qualifications due to the
domestic and local norms, regarding electrical installations
-
do not limit or cover the inlet and outlet of the device
-
do not install, service the device with wet hands or barefoot
-
the device should be kept out of reach of children and animals
-
when no need heating, turn off the heat source to use it as an unheated air
curtain
-
after the turn off, the elements of device may be warm
-
after operating time of the device, please utilize it concerning the local norms
and regulations
-
don’t allow water or any liquid to enter the motor
-
maintenance and repair work must be carried out by a qualified personnel
familiar with local regulations and standards
-
always unplug or disconnect the appliance from the power supply before
installation, servicing or cleaning the unit
-
never use petrol, benzene, thinners or any other chemicals for cleaning the unit
-
periodic maintenance work should be carried out at least once a year by:
ź
cleaning the heater and other elements from dust
ź
cleaning of plastic parts with water with the addition of soap
ź
cleaning the casing with a soft cloth
-
install the main body. Set the main body onto the upper end of the mounting
plate and clamp it as shown
4.
INSTALLATION INSTRUCTIONS