For heated rooms, set the steering wheel in the opposite direction to the room
with the curtain at an angle of 0 -15 degrees (see figure).
For canteens, kitchens, set the steering wheel towards the room with the curtain
at an angle of 0 -15 degrees (see figure).
2. DEVICE CHARCTERISTICS
2.1 DIMENSIONS
1. INTRODUCTION
1.1. PRECAUTIONS
1.2. TRANSPORT
1.3. PACKAGE CONTENT
1.4. USE
2. DEVICE CHARCTERISTICS
2.1 DIMENSIONS
2.2 TECHNICAL DATA
3. INSTALLATION
3.1. GENERAL PRINCIPLES
3.2. ASSEMBLY „STEP BY STEP”
4. INSTALLATION INSTRUCTIONS
4.1 CONNECTION OF THE DEIVCE TO THE ELECTRICAL SYSTEM
5. PRECAUTIONS AND WARNINGS
6. INSTRUCTION OF USE
6.1 CONTROL
6.2 OVERHEATING PROTECTION
7. CONNECTION SCHEMES
8. TERMS OF WARRANTY
1. INTRODUCTION
Thank you for purchasing Reventon Group air curtain. We would like to
congratulate on good choice. Please read and save these instructions.
1.1 PRECAUTIONS
The buyer and the user of the device should read carefully the following
instructions and proceed to the content recommendations. Proceeding due
to the following instruction guarantees the correct usage and safety. In case
of any doubts please contact the Reventon Group Sp. z o.o. The Supplier reserves
the rights to make changes to the technical documentation without previous
notice. The Supplier is not responsible for the damages which occur due
to improper installation, not keeping the device in repair or using the device out
of line. The installation should be carried out by the professional installers, who
possess the qualifications to install these types of devices. The installers are
responsible for making the installation as instructed in the technical data.
Regulations and safety rules must be followed. During the installation, use,
service and periodical inspections all regulations and safety rules must
be followed. In case of unserviceable please plug out the device and contact with
the authorized person or the Supplier. All safety requirements must be taken into
account during installation, use or inspection.
1.2 TRANSPORT
During the acceptance of goods it is needed to check the device in order
to exclude any damages. During the transport it is needed to use the proper
equipment, it is necessary to carry the device by two people. In case of any
damages please fill in the damage report in presence of the Supplier or the
carrier.
1.3
PACKAGE CONTEN
- air curtain
- operation and maintenance manual and warranty card
- assembly panel
- door sensor
- remote controller
1.4
USE
Air curtains are widely installed at the entrances of supermarkets, theaters,
meeting rooms, hotels, offices, storages etc. They can reduce penetration of
insects, outside dust, unconditioned air into a conditioned space by forcing an air
stream over the entire entrance. In winter they prevent uncontrolled heat loss
and in summer they prevent heat from the room (see figures). However, air
curtains should not be used in corrosive environments for aluminum, copper and
steel as well as in highly dusty environments (above 0,3 g/m³).The devices should
also not be installed in rooms where they would be exposed to high humidity or
direct contact with water.
consumption [A]
For air-conditioned rooms, the steering wheel must be set at an angle of 0-15
degrees towards the air-conditioned room (see figure).
SECURITY AGAINST INSECTS
AND ODORS
HEATED ROOM
INSIDE
OUTSIDE
A CLIMATED ROOM
ENG
TECHNICAL DATA
BACK
TECHNICAL DATA
AERIS 100E-1P
AC100E1P
Product code
AERIS 150E-1P
AC150E1P
AERIS 200E-1P
AC200E1P
Heater power [kW]
Current
Maximum airflow
[m3/h]
Maximum air speed
[m/s]
Power supply [V] / Frequency [Hz]
Maximum
motor power[W]
Rated motor
current [A]
C
lass of isolation /Protection degree IP [-]
Net weight [kg]
Noise
[dB]
26,1
14,3
20
17,4
29,1
40,9
8,7
43,5
60,9
1200
1900
2800
1100
1700
2500
8,5
8,5
8,5
7,5
7,5
7,5
230/50
230/50
230/50
15,5
20,5
26
57
59
61
55
57
59
E/IP20
E/IP20
E/IP20
III HEATING LEVEL
II HEATING LEVEL
I HEATING LEVEL
III HEATING LEVEL
II HEATING LEVEL
I HEATING LEVEL
6,0
3,3
4,6
4,0
6,7
9,4
2,0
10
14
I STAGE
II STAGE
I STAGE
II STAGE
I STAGE
II STAGE
I STAGE
II STAGE
I STAGE
II STAGE
180
230
350
130
180
300
2.2.TECHNICAL DATA
REVENTON GROUP
AERIS 100E-1P
REVENTON GROUP
AERIS 150E-1P
REVENTON GROUP
AERIS 200E-1P
90
105
195
265
N. W.
(kg)
15,5
20,5
26
INSIDE
OUTSIDE
INSIDE
OUTSIDE
consumption [A]
0,78
1,00
1,52
0,57
0,78
1,3